P R O G R A M M I N G
_________________________________________________________________________________
GsmAlarm-500
Software ver. 1.15
-
33-
5.7.7.
PARAMETER “P”: PARTITION ASSIGNMENT AND PARTIAL ARM METHODS.
TAMPER RECOGNITION
This parameter is defining if zone is operating in full or partial protection mode. Also, whether
tamper recognition is activated. Possible operating modes are described in detail in Chapter 5.3.1.3.
Default values for all zones programmed by manufacturer: 10.
5.7.8.
PARAMETER “I”: PULSE COUNTING MODE OR TEMPERATURE
HYSTERESIS
If the first digit of this parameter is larger than 1, the zone operates in the pulse counting mode. After
triggering of a zone the number of times Ni during the preset time Ti, the system switches over to the
alarm state. The first digit: the number of triggering events Ni. The second digit: the pulse counting
time Ti. Multiplication of the second number by 10 produces the time in seconds. Minimal time: 10
seconds (1), maximal time: 90 seconds (9). If Ni=0 or Ni=1, the pulse counting mode is switched off.
In temperature measuring mode this parameter comply temperature difference, at which triggered
zone returns to primary state.
The factory default values for all zones: 02.
Address
Parameter
281
Zone Z1 „P“ parameter
282
Zone Z2 „P“ parameter
283
Zone Z3 „P“ parameter
284
Zone Z4 „P“ parameter
285
Zone Z5 „P“ parameter
286
Zone Z6 „P“ parameter
287
Zone Z7 „P“ parameter
288
Zone Z8 „P“ parameter
Address
Parameter
289
Zone Z9 „P“ parameter
290
Zone Z10 „P“ parameter
291
Zone Z11 „P“ parameter
292
Zone Z12 „P“ parameter
293
Zone Z13 „P“ parameter
294
Zone Z14 „P“ parameter
295
Zone Z15 „P“ parameter
Address
Parameter
331
„I“ parameter of zone Z1
332
„I“ parameter of zone Z2
333
„I“ parameter of zone Z3
334
„I“ parameter of zone Z4
335
„I“ parameter of zone Z5
336
„I“ parameter of zone Z6
337
„I“ parameter of zone Z7
338
„I“ parameter of zone Z8
Address
Parameter
339
„I“ parameter of zone Z9
340
„I“ parameter of zone Z10
341
„I“ parameter of zone Z11
342
„I“ parameter of zone Z12
343
„I“ parameter of zone Z13
344
„I“ parameter of zone Z14
345
„I“ parameter of zone Z15