Part 2: Overview of display values and settings
Time Program for Solar
15
Time Program for Solar
Kick function enabling
Factory setting:
Mo. to Su.:
00:00 to 24:00
Heating time 1
Mo.-Su.
Area Time-Date
This area contains different values for the user in order to
provide rapid access.
Parameters on the Time-Date level
Time
(hh:mm)
Set hour, F button [==>],
hh:mm, set minutes
Date
(dd. mm yy)
Set year, F button [<==], set month,
F button [<==], set day,
Holiday begin
(dd. mm yy)
Set date for begin of the holiday
time
Holiday end
(dd. mm yy)
Set date for end of the holiday time
Start Summertime
(dd. mm.)
Set date for begin of clock change
Stop Summertime
(dd. mm.)
Set date for end of clock change
Parameters on the Time-Date level
Time
(Not for Time Master or DCF in the system)
!
There may be a time difference of up to 2 minutes
per month (correct time if necessary). If a DCF
receiver is connected the correct time is always
displayed.
Time Master for all controllers
!
If a heating system controller has been set to be
the Time Master (time setting for all controllers, see
Expert/Configuration) or a DCF (Radio time
receiver) has been installed in the system, the time
is blanked out on all the other controllers in the
system.
!
A max. of one Time Master can be set on the BUS.
Date
Please first set the year and then the month. Then the
number of days of the month are calculated during the
setting.
Holiday function
!
Please do not enter the day of travel as the start
date, but the first day of the holiday (no more
heating from this day).
!
Please do not enter the day of travel as the end
date, but the last day on which there is to be no
heating. When you arrive home the house should
be warm and there should be hot water.
!
Stop holiday function => e.g. for early return by
pressing the program switch.
Automatic summer/winter time changeover
The current weekday is calculated automatically. It is
shown the standard display.
It is possible to change from summer to winter time by
entering the date.
!
The default setting is valid for Central European
time zones. A modification is only required if the
date for the time change is changed by political
decree.
!
The earliest date on which the change will occur
must be set. The controller performs the time
change on the Sunday following this date at 2:00
am or 3:00 am.
!
If no time change is required, please set month
End to the same value as month start and day End
to the same value as day start.