Part 2: Overview of display values and settings
User
Area
11
User Area
All the settings that can be made by the operator of the
system.
Installation
Designation Value
range
Standard IV*)
Language
Acc. to version
English
LCD Contrast (0) – (6)
4
LCD
Brightness
00 – 30
30
°C / °F
Celsius, Fahrenheit Celsius
*) IV = Internal Values:
Space for entering the parameters stored in the system!
Hot-Water
Designation Value
range
Standard
IV
1x hot water
Off/On
Off
T-DHW 1 des
10°C – 70°C
60°C
T-DHW 2 des
10°C – 70°C
60°C
T-DHW 3 des
10°C – 70°C
60°C
BoB-Value
0K – 70K
0K
Circl-Pump DHW
OFF/ON
OFF
Antilegion OFF/ON
OFF
Installation
English => Language
Select controller language
LCD Contrast
Adjust intensity of display
LCD Brightness
Adjust the brightness of the display illumination.
°C / °F
Changeover between display of values in Celsius or
Fahrenheit.
Hot-Water
1x hot water (1x hot water)
On => The storage tank is enabled for charging
(e.g. for showering outside hot water times).
Charging starts when the temperature falls below "T-
DHW 1 des" by the switching hysteresis.
T-DHW des 1-3 (Hot water temperature setting)
Required hot water temperature setting
T-DHW 1 des => used in first enable time,
T-DHW 2 des => used in second enable time,
T-DHW 3 des => used in third enable time of hot water
program.
BoB-Value (Operation Without Burner)
Energy saving function for solar or solid fuel integration
For settings
> "0"
the burner is not activated for hot water
preparation until the hot water temperature has dropped
below the temperature setting by the set value + the
switching hysteresis.
Circl-Pump DHW (Circulation with hot water)
On => The circulation pump runs when the hot water is
enabled, but the circulation program is disabled.
Antilegion (Hot water short time heating function)
On => Activation of hot water short time heating function
Every 20th time that heating takes place or once per
week on Saturday at 01:00 hrs the storage tank is heated
up to 65°C.
It is possible to set up your own hot water short time
heating function using the third hot water enable facility.