Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Press the button to select the indoor sensor the control system will use for this venti-
lator (Pre-setting: Internal sensor at WS1, first sensor in the list at WS1000). As long as
“
No Sensor
” is selected, the indoor temperature and air humidity will not be taken
into account by the control system for this ventilator.
Confirm your setting with the
OK
button.
Press the button to set the indoor temperature above which the ventilation will be
switched on at night. Until an indoor sensor is selected, the indoor temperature will be
disregarded.
Setting the temperature: Adjust the value for the desired room temperature using the
arrow buttons. Pre-setting: 21.0 °C.
Roof Ventilator WS305/610, ventilation units at RF-VM module: The ventilator is
switched step by step, depending on the difference to the target temperature.
Air Supply Unit WFL, ventioaltor at multifunctional output or RF Relay: The ventilation
unit is opened as soon as the temperature exceeds the set value. It is closed again as
soon as the temerature drops more than 2.0°C below the set value (hysteresis).
Shutting off ventilation: If ventilation is to be independent of indoor temperature, press
the button labelled
OFF
.
Confirm your setting with the
OK
button.
Press the button to set the air humidity above which the ventilation will be switched on
at night. Until an indoor sensor is selected, the air humidity will be disregarded.
Setting humidity: Adjust the value for the desired humidity using the arrow buttons.
Pre-setting: 80%.
Shutting off ventilation: If ventilation is to be independent of air humidity, press the
button labelled
OFF
.
Confirm your setting with the
OK
button.
Press the button to set the supply air temperature block (summer operation). With WFL
supply air units, the supply air temperature is recorded by a thermometer integrated
into the WFL. With devices from other manufacturers the outdoor temperature at the
weather station is used as the supply air temperature.
Sensor Selection
For all ventilation units.
Indoor Temp
For all ventilation units.
Temp. Ventilation
Air Humidity
For all ventilation units.
Humidity Ventil.
Supply-Air Temp.
Only for WFL
and ventilation units at MF output/RF Relay.