77
Installation
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
The correct wind value may only be supplied about 30 seconds after the supply voltage
has been connected.
4.2.3. Maintenance of the weather station
WARNING!
Risk of injury caused by components moved automatically!
The automatic control can start system components and place people in
danger (e.g. moving windows/awnings if a rain/wind alarm has been
triggered while cleaning).
•Always isolate the device from the mains for servicing and cleaning.
The device must regularly be checked for dirt twice a year and cleaned if necessary. In
case of severe dirt, the sensor may not work properly anymore.
ATTENTION
The device can be damaged if water penetrates the housing.
•Do not clean with high pressure cleaners or steam jets.
4.3.
Installation of a WGTH-UP Indoor
Sensor
The WS1 Color control system has an indoor sensor integrated into the central unit.
Further external sensors can additionally be installed. The WS1000 Color control sys-
tem comes with an indoor sensor WGTH-UP included in the delivery.
The WGTH-UP Indoor Sensor transfers temperature and humidity to the control sys-
tem via radio. Several separate WGTH-UP can be taught to one control system. The
teaching is described in the chapter “Learn wireless connections” (manual of the con-
trol system).
The WGTH-UP Indoor Sensor consists of the housing, the sensor PCB/base plate and a
frame. As an alternative to the supplied frame, a frame of the switch series used in the
building may be used. You will additionally require a junction box (Ø 60 mm, 42 mm
deep, not included in scope of delivery).
For power supply (7...30 V DC), e. g. 12 V DC can be tapped from the connection board
of the control unit (multifunctional input).