If a smoke detector is connected, ventilation will be activated automatically when there
is a fire alarm.
Automatic functions for light:
•
Switch on daily (settable running times, with and without twilight recognition)
•
Switch on at twilight
•
Switch on when an alarm triggers (motion/smoke detector)
Automatic functions for roof gutter heatings:
•
Switch on within an adjustable temperature range
Automatic alarm settings:
•
Motion detector: The period of alarm readiness is adjustable. If the alarm is
triggered within this period, all windows close. After 5 minutes without a new
alarm signal, normal automatic operation will be resumed.
•
Smoke detector: When the alarm triggers, shades retract (escape routes),
windows open, ventilators open/switch on (getting rid of smoke) and heatings
and air conditioners switch off. No manual operation is possible. An acoustic
warning signal will sound at the control system.