A
heating or climate unit
(climate detector) that works independent of the control
unit can be connected to a multifunctional input with its potential-free relaiy contact.
The device signals the control via the closed relay contact that it is heating or cooling.
The control then closes all windows and switches off the ventilators. If the device
opens the relay contact again, the control will hold the windows closed for a variable
time and leave the ventilators switched off.
3.3. Adjust ventilation block
A
safety contact
can be connected to the multifunctional inputs which will then be
assigned to a drive output. If the safety contact is opened, then the drive will advance
to the safe position (window closes, shade retracts) and manual operation is blocked.
This can ensure that the blind on a terrace door can't descend if the door is open. Take
note that a safety contactis not capable of preventing collisions (e.g. if an awning is in-
stalled over a window).
A
closed contact
can be used on a multi-function input in order to determine if a slid-
ing door is completely closed.
The multifunctional inputs may be used as the trigger for
automatic reset
. The input
impulse may come e.g. following the pressing of a button or alarm activation.
If cameras are connected to the control system, the setting
Binary Input
can be used
to activate the image display. For example, the signal can be connected to a bell on a
multifunctional input and this can be configured as a binary input. Then the image of
a camera can be shown in the screen as soon as the bell is rung.
The settings for the multifunctional inputs can be accessed by pressing the buttons:
You can now select individual inputs from the List and adjust their settings. So long as
no settings were completed yet, the buttons show (
MF Input 1
), (
MF Input 2
) etc. If
an output was already configured, the function and/or name will be displayed instead.
Press the button of the input to be set. For each multifunctional input the following set-
tings can be changed:
Input type
Press the
Reserve
button. The possible input types appear (motion detector, smoke
detector, climate detector, closed detector, automatic reset, binary input). Select as ap-
propriate. If a multifunctional input is not being used for the moment, leave “Reserve”.
Confirm your selection with the
OK
button.
Installation
Multif. Input
System
Reserve
Summary of Contents for 60121
Page 7: ...6 Clarification of signs ...