Description
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
•
Leave open until a selectable indoor temperature is reached
(can be switched off)
•
Close at night/twilight Leave open until
•
Close daily (settable running times)
•
Outdoor temperature block: Block beneath a selectable outdoor temperature
(can be switched off)
•
Frost alarm: Retract in case of precipitation beneath a selectable outdoor
temperature (can be switched off)
•
Wind alarm: Retract when a selectable wind speed is exceeded (can be
switched off)
•
Rain alarm: Retract when there is precipitation (can be switched off)
If a smoke detector is connected, shutters will be opened automatically when a fire
alarm is triggered.
Automatic functions for heatings:
•
Switch on daily below a selectable indoor temperature
•
Night setback (with adjustment of time and temperature until the setback is
made)
If a smoke detector is connected, the heating will be automatically switched off when
a fire alarm is triggered.
Automatic functions for coolings and air-conditioning units:
•
Switch on daily above a selectable indoor temperature
•
Night mode (with adjustment of time and temperature until cooling takes
place)
•
Cancel ventilation when cooling/air-conditioning unit is active
If a smoke detector is connected, the cooling will be automatically switched off when
a fire alarm is triggered.
Automatic ventilation functions:
•
Ventilation above a selectable indoor temperature (can be switched off)
•
Ventilation above a selectable air humidity level in the room
(can be switched off)
•
Winter operation: supply air will be closed below a selectable outdoor
temperature (can be switched off)
•
Summer operation: supply air will be shut off if outdoor temperature is higher
than room temperature
•
Adjustable minimum and maximum speeds for motorised fans
•
Night-time re-cooling (settable running times)
•
Daily forced ventilation (settable running times)
•
Additionally with roof ventilators WL610 and WL305: recirculating air for heat
recovery; recirculating air to avoid condensation
•
Cancel ventilation when cooling/air-conditioning unit is active