Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Switching off: To switch off the window’s Reset function, select
No
(this is the default
setting).
Confirm your setting with the
OK
button.
Automatic Reset time and/or period can be set.
System > Automatic Settings > General Settings > Automatic Reset
3.3. Define automatic reset
3.1.7. Automatic ventilation settings
For connected roof ventilation units and supply air units the following automatic set-
tings can be changed:
•
Indoor sensor to be used for the ventilation unit
•
Indoor temperature
•
Air humidity
•
Air supply temperature (only for air supply devices)
•
Exhaust air levels (only for roof ventilators WL610/WL305)
•
Night-time re-cooling (together with indoor temperature for night-time re-
cooling)
•
Timed ventilation (and levels for timed ventilation)
•
Outdoor temperature (only for air supply devices)
•
Recirculating air for heat recovery (only roof ventilators WL610/WL305)
•
Recirculating air for condensation reduction (only for roof ventilators WL610/
WL305)
•
Temperature for heating (only for fresh air/heating-combos on RF-VM)
•
Enable/Disable automatic reset
In the event of a fire alarm from a smoke detector, ventilation is activated and cannot
be influenced by either the automatic or the manual.
As soon as a connected air conditioner is activated, ventilation is disabled, including
manually activated fans. The fans can be manually operated again immediately. The
delay time for the ventilation block can be adjusted.
System > Automatic Settings > General Settings > Ventilation Block
3.3. Adjust ventilation block
The automatic ventilation functions can be accessed by pressing the buttons:
Now you can select individual ventilators and adjust their settings. For each ventilator
the following settings can be changed:
Automatic
Settings
Ventilation
System