50
Automatic settings
Control System WS1 Color / WS1000 Color
• Version: 14.12.2016 • Technical changes and errors excepted.
Enable: If the supply air unit should be closed when the supply air temperature is
warmer than the room temperature, select
Yes
.
Disable: If the supply air unit should also then be/remain open when the supply air tem-
perature is warmer than the room temperature, select
No
(default setting).
Confirm your setting with the
OK
button.
Press the button to set the ventilation levels of the motorised roof ventilators. The fur-
ther the indoor temperature and air humidity lie above the reference values, the higher
the ventilator shifts.
Use the arrow buttons to change the start and maximum values according to your
wishes. Default setting: Start with level 1, maximum level 8 (full level utilisation).
Confirm your setting with the
OK
button.
Press the button to set the times for night-time re-cooling. The button is only activated
once the general settings for night-time re-cooling have been configured.
System > Automatic Settings > General Settings > Night-time Cooling
3.3. Set night-time re-cooling (ventilation)
Press
Select
to select the time during which the night-time re-cooling will operate. Ac-
tivate one or more periods on the list.
Confirm your setting with the
OK
button.
To change any of the time periods, press
Timer
.
3.3. Set timer
Be careful that your settings for timed closure do not prevent night-time re-cooling op-
erations! A set supply air temperature block can also prevent night-time re-cooling.
Press the button to set the indoor temperature to the desired cooling level (for the
night-time re-cooling). The button is only activated once a night-time re-cooling period
has been set.
Use the arrow keys to change the value as required. Default setting: 16.0°C.
Confirm your setting by pressing
OK.
Exhaus Air Levels
Only for WL610/WL305 and
air supply on RF-VM.
Ventilation Levels
Night-time Cooling
Not on fresh air/heating-combos on RF-VM.
NTC Indoor Temp.