PG4UW
Swap bytes operation from Start address 0 to End address N modifies data in buffer by
following tables:
Address
Original
Data
Swap 2-bytes
inside 16-bit
words
Swap 4-bytes
inside 32-bit
words
Swap
nibbles
inside bytes
Mirror bits
inside
bytes
0000h b0
b1
b3
b0n
b0m
0001h b1
b0
b2
b1n
b1m
0002h b2
b3
b1
b2n
b2m
0003h b3
b2
b0
b3n
b3m
0004h b4
b5
b7
b4n
b4m
0005h b5
b4
b6
b5n
b5m
0006h b6
b7
b5
b6n
b6m
0007h b7
b6
b4
b7n
b7m
b0, b1, b2, ... means original buffer byte values from addresses 0, 1, 2, ...
b0n, b1n, b2n, ... means nibble-swapped original bytes b0, b1, b2, ... by following rules:
Original Byte bits
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Nibble-swapped Byte Bits
bit 3
bit 2
bit 1
bit 0
bit 7
bit 6
bit 5
bit 4
Original Byte bits
bit 7
bit 6
bit 5
bit 4
bit 3
bit 2
bit 1
bit 0
Mirrored Byte Bits
bit 0
bit 1
bit 2
bit 3
bit 4
bit 5
bit 6
bit 7
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note:
Address history values are common for all buffer data manipulation dialogs.
Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.
Buffer / Erase
If this command is selected, the content of the buffer will be filled with topical blank character.
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
Note: Address history values are common for all buffer data manipulation dialogs.
Default address range is set according to buffer range of selected device.
Selecting option "Maintain last inserted values" causes that for the next time you open this
dialog, previously confirmed values will be reloaded as default.
The reserved key
<Ctrl+F2>
will bring out this menu from any menu and any time.
Buffer / Fill random data
If this command is selected, the content of the buffer will be filled with random data.
Selecting option "Allow address history logging" activates saving of recently confirmed values.
These are saved for each device separately, count is limited to last 15 items.
91
Summary of Contents for SEEprog
Page 7: ...Introduction Introduction 7...
Page 12: ...ELNEC s r o Quick Start 12...
Page 15: ...Detailed description Detailed description 15...
Page 16: ...ELNEC s r o BeeHive204 16...
Page 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Page 45: ...SmartProg2 SmartProg2 45...
Page 54: ...ELNEC s r o MEMprog2 54...
Page 61: ...SEEprog SEEprog 61...
Page 66: ...ELNEC s r o Setup 66...
Page 77: ...PG4UW PG4UW 77...
Page 144: ...ELNEC s r o PG4UWMC 144...
Page 154: ...ELNEC s r o Common notes 154...
Page 168: ...ELNEC s r o Troubleshooting and warranty 168...