Actual serialization settings for actually selected device are saving to disk along with
associated device by
File / Exit and save
command.
When incremental mode is active following actual settings are saved to configuration file:
address, size, serial value, incremental step and settings of modes ASCII / BIN, DEC / HEX,
LS byte / MS Byte first.
When from-file mode is active following actual settings are saved to configuration file: name
of input serialization file and actual label, which indicates the line with actual serial number in
input file.
When program is in multiprogramming mode (multiple socket programmer is actually
selected) the special section -
Action on not programmed serial values due to error
- is
displayed in dialog
Serialization
. In this section two choices are available:
•
Ignore not programmed serial values
•
Add not programmed serial values to file
Ignore not programmed serial values
means the not programmed serial values are ignored
and no action is done with them.
Add not programmed serial values to file
means the not programmed serial values are
added to file. The file of not programmed serial values has the same text format as
serialization file for ”From-file” serialization mode. So there is possible to program the serial
values later on by ”From-file” serialization mode.
Notes:
If device programming is stopped by user, program will not change the serial values
ready for next batch of devices. The same situation is if device program is incomplete, e.g. for
device insertion test error.
Ignoring or writing not programmed serial values is only used when at least one device from
current batch of devices in multiple socket module programmer is completely programmed
and verified without errors.
Serialization can work with control program's main buffer or extended buffers available for
some types of devices, for example Microchip PIC16Fxxx devices with Data EEPROM
Memory. The selection which buffer has to be used by serialization routine is available in
dialog Serialization. The extended buffer selection is ignored for From-file serialization in
playlist file mode. For more details about this limitation, see the
From file mode
serialization
mode description please.
If you wish to exclude serialization data from main checksum automatic calculation, you can
use
Exclude buffer data for checksum
feature available in dialog Checksum in tab
Main
checksum options
.
Device / Device options / Serialization / Incremental mode & SQTP
The
Incremental mode & SQTP
enables to assign individual serial numbers to each
programmed device. A starting number entered by user will be incremented by specified step
for each device program operation and loaded in selected format to specified buffer address
prior to programming of each device.
There are following options, that user can modify for incremental mode:
S / N size
102
Summary of Contents for SEEprog
Page 7: ...Introduction Introduction 7...
Page 12: ...ELNEC s r o Quick Start 12...
Page 15: ...Detailed description Detailed description 15...
Page 16: ...ELNEC s r o BeeHive204 16...
Page 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Page 45: ...SmartProg2 SmartProg2 45...
Page 54: ...ELNEC s r o MEMprog2 54...
Page 61: ...SEEprog SEEprog 61...
Page 66: ...ELNEC s r o Setup 66...
Page 77: ...PG4UW PG4UW 77...
Page 144: ...ELNEC s r o PG4UWMC 144...
Page 154: ...ELNEC s r o Common notes 154...
Page 168: ...ELNEC s r o Troubleshooting and warranty 168...