![Elnec SEEprog User Manual Download Page 37](http://html1.mh-extra.com/html/elnec/seeprog/seeprog_user-manual_2395127037.webp)
BeeProg2 / BeeProg2C /
Comment to above picture:
picture C) Connection of pins 15 and 16 when are configured as logical signal needed for ISP
programming
pictures D) E) When pins 15 and 16 are configured as status of LED OK and LED ERROR
picture D) before first action with desired ISP device
picture E) after first action with desired ISP device
Notes:
When LED OK or LED ERROR ON (shine), this status is presented as logical H, level
of H is 1,8V - 5V depend on H level of desired ISP device.
When LED OK or LED ERROR OFF (not shine), this status is presented as logical L, level of
L is 0V - 0,4V.
The above mentioned values are provided to understand (and also to exactly calculate) the
value of resistors, which isolate (separate) the programmed chip and target system.
Specification of ISP connector pins depends on the device, which you want to program. You
can find it in the control SW for programmer (PG4UW), menu
Device / Device Info (Ctrl+F1)
.
Be aware, the ISP programming way of respective device must be selected. It is indicated by
(ISP) suffix after name of selected device.
These specifications correspond with application notes published of device manufacturers.
Used application notes you may find on
section Support / Application
Notes.
Note:
Pin no. 1 is signed by triangle scratch on ISP cable connectors
.
As ISP connectors are used 20 pins connectors 09185207813 from Harting or other
compatible connector.
BeeProg2 / BeeProg2C / ISP cable
Warnings:
•
When
you use BeeProg2 /
BeeProg2C / as
ISP programmer
,
don’t insert
device to
ZIF socket
.
•
When
you program devices in
ZIF socket
,
don’t insert
ISP cable to
ISP connector
.
•
Use only
attached ISP cable
. When you use other ISP cable (other material, length…),
programming may occur unreliable.
•
BeeProg2 / BeeProg2C /
can
supply
programmed device (pin 1 of ISP
connector) and target system (pins 19 and 20 of ISP connector) with limitation (see
Technical specification / ISP connector).
•
BeeProg2 / BeeProg2C / apply programming voltage to target device and
checks his value (target system can modify programming voltage). If the programming
voltage is different as expected, no action with target device will be executed.
37
Summary of Contents for SEEprog
Page 7: ...Introduction Introduction 7...
Page 12: ...ELNEC s r o Quick Start 12...
Page 15: ...Detailed description Detailed description 15...
Page 16: ...ELNEC s r o BeeHive204 16...
Page 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Page 45: ...SmartProg2 SmartProg2 45...
Page 54: ...ELNEC s r o MEMprog2 54...
Page 61: ...SEEprog SEEprog 61...
Page 66: ...ELNEC s r o Setup 66...
Page 77: ...PG4UW PG4UW 77...
Page 144: ...ELNEC s r o PG4UWMC 144...
Page 154: ...ELNEC s r o Common notes 154...
Page 168: ...ELNEC s r o Troubleshooting and warranty 168...