ELNEC s. r. o.
job_report_<ordnum>_<prjname>.jrp
where
<ordnum> is decimal order of the file. If there exist any report files with the same name, then
order for new report file is incremented about order of existing files.
<prjname> is project file name of recently used project, and without the project file name
extension.
Example 1:
Let's use the project file c:\myproject.eprj and directory for Job Report set to d:\job_reports\.
There are no report files present in the Job Report directory.
The final Job Report file name will be:
d:\job_reports\job_report_000_myproject.jrp
Example 2:
Let's use the conditions from Example 1, but assume there is already one report file present.
Name of this file is d:\job_reports\job_report_000_myproject.jrp
The final Job Report file name of new report will be:
d:\job_reports\job_report_001_myproject.jrp
Note, the order inside file name is incremented by 1.
When
Automatically save Job Report file
setting is set, no Job Report dialogs appears
when generating Job Report. Newly generated Job Report is saved to file without any dialogs
or messages (if no error occurs while saving to file).
If the checkbox
Automatically save Job Report file
is unchecked, the PG4UW will show
Job Report dialog every time needed.
In the Job Report dialog user can select operation to do with Job Report. If user selects no
operation (Close button), the Job Report will be written to PG4UW Log Window only.
Automatic YES!
Allows user to override default settings (as preset in PG4UW software) of indication for the
state when the programmer and the software wait for withdrawing programmed device and a
new one will be inserted in active Automatic YES! mode.
Default (as preset in software)
- the programmer indicates the state when a device is
programmed and the programmer with software wait for inserting a new device as preset in
the software for respective programmer. Multi-sockets programmers (the programmers with
more than one ZIF socket) do not indicate this state, see description for
Not indicated (quiet
mode)
. Single-socket programmers (the programmers with one ZIF socket) indicate this state
by LED Busy blinking, see description for
By LED Busy blinking
setting.
Not indicated (quiet mode)
– the programmer, regardless of the number of ZIF sockets of
the programmer, does not indicate the state when a device is programmed and the
programmer with software wait for inserting a new device. After an operation with a device
only one of the status LEDs Error or OK lights, in dependence on the result of previous
operation. This LED goes off immediately after detecting removal of a device from the ZIF
socket.
134
Summary of Contents for SEEprog
Page 7: ...Introduction Introduction 7...
Page 12: ...ELNEC s r o Quick Start 12...
Page 15: ...Detailed description Detailed description 15...
Page 16: ...ELNEC s r o BeeHive204 16...
Page 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Page 45: ...SmartProg2 SmartProg2 45...
Page 54: ...ELNEC s r o MEMprog2 54...
Page 61: ...SEEprog SEEprog 61...
Page 66: ...ELNEC s r o Setup 66...
Page 77: ...PG4UW PG4UW 77...
Page 144: ...ELNEC s r o PG4UWMC 144...
Page 154: ...ELNEC s r o Common notes 154...
Page 168: ...ELNEC s r o Troubleshooting and warranty 168...