Elnec s. r. o.
172
7. After direction of control program, disconnect other ISP cable connector from target
system and turn off it.
8. If you need another action on target device, you continue with step 5.
The recommendation for design of target system with ISP programmed
device
The target system must be designed to allow all signals, which are use for In-system
programming to be directly connected to ISP programmer via ISP connector. If target system
use these signals for other function, is necessary isolated these signals. Target system mustn’t
affect these signals during In-system programming.
For in-system programmable devices manufacturers publish application notes. Design of Elnec
programmers together with respect of these application notes allows proper In-system
programming. Condition is exactly respecting these application notes. Applications notes,
which Elnec use in ISP programmers, are published in
, section
Support /
Application Notes
.
Please, read some notes for following recommended circuits.
Purpose of D1 diode is to protect the target circuit against a higher voltage, which is provided
by ISP programmer.
If your target board supply differs from mentioned 5V, choose please the Zener diode (D1)
voltage according to this supply voltage.
We recommend using resistors R1, R2, (R3) to separate the target device from target
system. If pins needed for ISP programming are inputs in target system then separation by
resistors is sufficient and resistors make a low pass filter too. If pins are outputs, then use of
resistors saves a programming time. Of course the isolation resistors R1, R2, (R3) can be
replaced by switches or jumpers, if necessary. In that case, during the ISP programming of
target device the switches (jumpers) must be open. But the using of switches (jumpers) adds
a next manipulation time to programming procedure.
Example of application note
Microcontrollers Atmel AVR and AT89Sxxx series
This interface corresponds with Atmel application note AVR910: In-System Programming. This
application note describes the recommended ISP interface connector layout in target system
(top view).
Elnec recommended circuit for ATMEL AVR:
ISP connector
target device
target system
reset circuit
R2
R3
GND
C1
22n
GND
VCC
GND
D2
1N4148
GND
R11
100k
C2
1u/10V
VCC
SCK
MISO
RESET
GND
I1
ATMEL AVR
DATA OUT
SCK
RESET
R1
MOSI
DATA IN
GND
target VCC check only
Summary of Contents for BeeHive204
Page 7: ...Introduction 7 Introduction ...
Page 12: ...Elnec s r o 12 Quick Start ...
Page 15: ...Detailed description 15 Detailed description ...
Page 16: ...Elnec s r o 16 BeeHive204 ...
Page 33: ...BeeProg2 BeeProg2C 33 BeeProg2 BeeProg2C ...
Page 50: ...Elnec s r o 50 SmartProg2 ...
Page 59: ...Setup 59 Setup ...
Page 66: ...Elnec s r o 66 PG4UW ...
Page 141: ...PG4UWMC 141 PG4UWMC ...
Page 162: ...Elnec s r o 162 Common notes ...
Page 176: ...Elnec s r o 176 Troubleshooting and warranty ...