Common notes
165
/Saveproject:... is equivalent to user selected command
Save project in PG4UW control program.
Please note, the file name Windows conventions must be fulfilled. It means also, that when file
name contains spaces, the command line parameter must have the file name bounded inside
quotation marks.
Examples:
/prj:c:\myfile.eprj
Load project file with name c:\myfile.eprj.
/loadfile:"c:\filename with spaces.bin"
Load file "c:\filename with spaces.bin" to buffer.
/Program[:switch]
forces start of ”Program device” operation automatically when
program is starting, or even if program is already running, also one
of following optional switches can be used:
switch 'noquest'
forces start of device programming without question
switch 'noanyquest'
forces start of device programming without question and after
operation on device is completed, program doesn't show "Repeat"
operation dialog and goes directly into main program window
Examples:
/Program
/Program:noquest
/Program:noanyquest
/Close
this parameter has sense together with /Program parameter only,
and makes program to close automatically after device programming
is finished successfully
/Close: always
this parameter has sense together with /Program parameter only,
and makes program to close automatically after device programming
is finished, no matter if device operation was successful or not.
Basic rules for using of executive command line parameters:
command line parameters are not case sensitive
command line parameters can be used when first starting of program or when program is
already running
if program is already running, then any of command line operation is processed only when
program was not busy (no operation was currently executing in program). Program must be
in basic state, i.e. main program window focused, no modal dialogs displayed, no menu
commands opened or executed.
order of processing command line parameters when using more parameters together is
defined firmly as following:
1. Load project (/Prj:...)
2. Load file (/Load file:...)
3. EPROM/Flash select by ID
4. Program device (/Program[:switch])
5. Close of control program (/Close only together with parameter /Program)
Summary of Contents for BeeHive204
Page 7: ...Introduction 7 Introduction ...
Page 12: ...Elnec s r o 12 Quick Start ...
Page 15: ...Detailed description 15 Detailed description ...
Page 16: ...Elnec s r o 16 BeeHive204 ...
Page 33: ...BeeProg2 BeeProg2C 33 BeeProg2 BeeProg2C ...
Page 50: ...Elnec s r o 50 SmartProg2 ...
Page 59: ...Setup 59 Setup ...
Page 66: ...Elnec s r o 66 PG4UW ...
Page 141: ...PG4UWMC 141 PG4UWMC ...
Page 162: ...Elnec s r o 162 Common notes ...
Page 176: ...Elnec s r o 176 Troubleshooting and warranty ...