The COMMS STATUS parameter (Tag 272) in the COMMS CONTROL function block monitors the sequencing
of the Inverter. It is a 16-bit word based on standard fieldbus drive profiles. Some bits are not implemented in the
initial release and are set to 0 (see “Supported” column of the table below).
Bit
Bit
Name
Name
Description
Description
Supported
Supported
0
Ready To Switch On
√√
1
Switched On
Ready for operation (refer control bit 0)
√√
2
Operation Enabled
(refer control bit 3)
√√
3
Fault
Tripped
√√
4
(Not) Voltage Disabled
OFF 2 Command pending
√√
5
(Not) Quick Stop
OFF 3 Command pending
√√
6
Switch On Disable
Switch On Inhibited
√√
7
Warning
8
SP / PV in Range
9
Remote
= 1 if Drive will accept Command Word
√√
10
Setpoint Reached
11
Internal Limit Active
12
13
14
15
Ready To Switch On
Same as the SWITCH ON ENABLE output parameter of the SEQUENCING LOGIC function block.
Switched On
Same as the SWITCHED ON output parameter of the SEQUENCING LOGIC function block.
Operation Enabled
Same as the READY output parameter of the SEQUENCING LOGIC function block.
Fault
Same as the TRIPPED output parameter of the SEQUENCING LOGIC function block.
(Not) Voltage Disabled
If in REMOTE COMMS mode, this is the same as Bit 1 of the COMMS COMMAND parameter. Otherwise it is
the same as the /COAST STOP input parameter of the SEQUENCING LOGIC function block.
(Not) Quick Stop
If in REMOTE COMMS mode, this is the same as Bit 2 of the COMMS COMMAND parameter. Otherwise it is
the same as the /FAST STOP input parameter of the SEQUENCING LOGIC function block.
Switch On Disable
Set (=1) only when in START DISABLED state.
Remote
This bit is set (= 1) if the Inverter is in Remote mode AND
AND the parameter REMOTE COMMS SEL of the COMMS
CONTROL function block is Set (= 1).
Summary of Contents for SINUS/ISD 200 S-0.75
Page 56: ...15P0082B8 USER MANUAL SINUS ISD 5 14 14...
Page 144: ...15P0082A8 USER MANUAL SINUS ISD 8 2 2...
Page 166: ...15P0082B8 USER MANUAL SINUS ISD 10 16 16...
Page 180: ...15P0082B8 USER MANUAL SINUS ISD 12 8 8...
Page 184: ...15P0082A8 USER MANUAL SINUS ISD 14 2 2...
Page 186: ...15P0082B8 USER MANUAL SINUS ISD 15 2 12 MACRO1 MACRO1...
Page 188: ...15P0082B8 USER MANUAL SINUS ISD 15 4 12 MACRO2 MACRO2...
Page 190: ...15P0082B8 USER MANUAL SINUS ISD 15 6 12 MACRO3 MACRO3...
Page 192: ...15P0082B8 USER MANUAL SINUS ISD 15 8 12 MACRO4 MACRO4...
Page 194: ...15P0082B8 USER MANUAL SINUS ISD 15 10 12...
Page 195: ...SINUS ISD 15P0082B8 USER MANUAL 15 11 12...
Page 196: ...15P0082B8 USER MANUAL SINUS ISD 15 12 12...
Page 200: ...15P0082B8 USER MANUAL SINUS ISD 16 4 10...