SINUS-K
PROGRAMMING
MANUAL
109/
226
6.3.9.
S
LIP
C
OMPENSATION
S
UBMENU
The Slip Compensation submenu determines the parameters relating to the slip compensation function. For more
details, see section 3.3 “SLIP COMPENSATION”.
Access page
Press PROG (Ent) to access the first page of the Slip Compensation submenu. Press
↑
(Nxt) and
↓
(Prv) to scroll through
the submenus.
First page
Press PROG (Esc) to return to the Slip Compensation submenu access page. Press
↑
(Nxt) and
↓
(Prv) to scroll through
the parameters.
PARAMETERS OF THE SLIP COMPENSATION SUBMENU
C74 Poles 2/6
P
C74
R
2, 4, 6, 8, 10, 12, 14, 16.
D
4
P = *
F
Number of motor poles for the calculation of the motor rotation speed.
C75 Motor 3/6
P
C75
R
0.5÷1000 KW
D
Column “Pnom”, Table 6.4
power = ** kW
F
Rated power of the connected motor.
C76 No load 4/6
P
C76
R
1÷100%
D
40%
current =****%
F
Determines the motor no–load current expressed as a percentage of the motor rated
current.
C77 Motor 5/6
P
C77
R
1÷10%
D
0%
slip = ****%
F
Determines the motor rated slip expressed as a percentage. Setting it to 0 disables this
function.
PROG SAVE
Menu Slip comp.
Ent Prv Nxt
PROG SAVE
Slip comp. 1/6
Ent Prv Nxt