-54-
8.4: Entry Deviation
Entry Deviation is a pre-alarm feature employed in the event that a sensor defined with
the “Normal” zone type is opened during the entry delay. In this case, the control
system’s built-in siren is sounded until the end of the entry delay period. Failure to disarm
by the end of the entry delay causes the system to generate an alarm.
To program the Entry Deviation setting:
1. From the Programming menu, select Entry/Exit, Ent. Deviation [925].
2. Select Enabled or Disabled.
8.5: Exit Restart
Exit Restart is a feature that is designed to prevent false alarms caused by user error
during exit. If this feature is enabled, re-opening a closed Entry/Exit zone during the
remainder of the Exit delay causes the Exit delay to re-start. For example, the Exit delay
is programmed as 60 seconds. The user arms the system and leaves the premises. With
10 seconds remaining, the user re-enters the premises and the Exit delay starts to count
down again from 60 seconds.
To program the Entry Deviation setting:
1. From the Programming menu, select Entry/Exit, Exit Restart [926].
2. Select Enabled or Disabled.
3. Press
when the desired setting is displayed.
8.6: Arming Tones
Arming tones are the tones sounded by the control system’s built-in siren and/or the
wireless siren when arming and disarming the system. Each set of tones can be enabled
or disabled according to the requirements of the installation.
8.6.1: Exit Delay Tones
To program tones sounded by the wireless siren during the Exit delay:
1. From the Programming menu, select Tones, Exit Tones, WL Siren [9311].
2. Select Enabled or Disabled.
To program tones sounded by the built-in siren during the Exit delay:
1. From the Programming menu, select Tones, Exit Tones, Siren [9312].
2. Select No Tones, Four Tones or Continuous Tones.
8.6.2: Entry Delay Tones
To program tones sounded by the wireless siren during the Entry delay:
1. From the Programming menu, select Tones, Entry Tones, WL Siren [9321].
2. Select Enabled or Disabled.
To program tones sounded by the built-in siren the Entry delay:
1. From the Programming menu, select Tones, Entry Tones, Siren [9322].
2. Select No Tones, Four Tones or Continuous Tones.
8.6.3: Arming Tones
To program tones sounded by the wireless siren on arming:
1. From the Programming menu, select Tones, Arm Tones, WL Siren [9331].
2. Select Enabled or Disabled.
Summary of Contents for infinite prime
Page 1: ......
Page 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Page 87: ... 87 ...
Page 88: ... 88 ...
Page 89: ... 89 ...
Page 90: ... 90 ...
Page 91: ... 91 ...
Page 92: ... 92 ...
Page 112: ......
Page 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...