Chapter Nine: System Options
As the name suggests, System Options are settings that affect the entire system. This
chapter offers explanations and programming instructions for each of these options.
9.1: Swinger Setting
A sensor defined as Swinger enabled can generate only a limited number of alarms during
a specific time period or during an arming period. The following options are available:
•
One alarm per arming period
•
One alarm per hour
•
One alarm per day
•
One alarm per week
•
No
swinger
To program the Swinger setting:
1. From the Programming menu, select System Options, Swinger [9401].
2. Select a Swinger setting from the above list.
9.2: Code Lockout
The Code Lockout option locks the keypad for 30 minutes if five unsuccessful attempts
are made to enter the user code.
To program the Code Lockout setting:
1. From the Programming menu, select System Options, Code Lockout [9402].
2. Select Enabled or Disabled.
,
During the 30-minute lockout period, you can still arm and disarm the system using
keyfobs and smartkeys. If one key arming is enabled, you may still arm the system using
the wireless keypad.
9.3: Arm/Disarm Options
The options offered in this section relate to arming and disarming the system.
9.3.1: Forced Arm
Forced arming enables you to arm the system when the system is not ready. This option allows
you to enable or disable Forced arming for the entire system. Additionally, you can enable or
disable Forced arming for each individual zone. For further information,
see
7.6.5: Force Arm
.
To program the Forced Arm setting:
1. From the Programming menu, select System Options, Arm/Disarm,
Forced Arm [94031].
2. Select Enabled or Disabled.
9.3.2: One-Key Arming
You can arm the system by pressing any of the three arming keys on the keypad. If One-
Key Arming is enabled, the system does not prompt you for a user code.
To program the One-Key Arming setting:
1. From the Programming menu, select System Options, Arm/Disarm, One-
Key Arming [94032].
2. Select Enabled or Disabled.
Summary of Contents for infinite prime
Page 1: ......
Page 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Page 87: ... 87 ...
Page 88: ... 88 ...
Page 89: ... 89 ...
Page 90: ... 90 ...
Page 91: ... 91 ...
Page 92: ... 92 ...
Page 112: ......
Page 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...