To program the Daylight Savings option:
1. From the Programming menu, select System Options, Daylight
Savings [9416].
2. Select Europe, USA or Disabled.
9.17: Report Fail Trouble
If the Report Fail Trouble option is enabled, failure to report an event displays System
Trouble on the LCD display. Report Fail Trouble is displayed after the control system has
exhausted all message attempts and report cycles when trying to report the event. To
restore a System Trouble condition caused by failure to report, press until you have
scrolled through the entire system trouble list. If the Report Fail Trouble is disabled,
failure to report an event does not cause a system trouble condition.
To program the Report Fail Trouble option:
1. From the Programming menu, select System Options, Rep. Fail Trb. [9417].
2. Select Enabled or Disabled.
9.18: Cancel Alarm
The Cancel Alarm feature allows the user to cancel a false alarm by disarming the system
within five minutes since the alarm is reported. The Control System reports a Cancel event
to the central station and enters an Alarm Canceled event in the event log. Following a
canceled alarm, the message
Alarm Canceled
,
OK?
appears on the keypads’ LCD. Until
the user presses
to confirm, the Control System does not allow any local function to be
performed. However, the Control System may perform remote commands received via
Telecontrol or Remote Programming regardless of its system status.
To program the Cancel Alarm option:
1. From the Programming menu, select System Options, Cancel Alarm. [9418].
2. Select Enabled or Disabled.
9.19: Cross Zoning (future option)
Cross Zoning is a future option that is not available in the current firmware. The default
setting for this option is disabled. Electronics Line 3000 recommend that you do not
change this setting.
9.20: Verified Fire
The Verified Fire feature is an option that is designed to delay Fire alarm reports to the
central station until the alarm condition has been verified. Local Fire alarm indication is
not affected by this option and the control system shall sound the siren instantly on
receiving an alarm from a smoke detector. You can program a Verified Fire timeout of
between 00 and 60 seconds (00 = disabled).
If the Verified Fire feature is enabled, a Fire alarm event shall be reported if…
•
An alarm occurs from a Fire zone and the alarm has not been restored by the
end of the Verified Fire timeout – in this case, the alarm is reported at the end of
the Verified Fire timeout.
Summary of Contents for infinite prime
Page 1: ......
Page 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Page 87: ... 87 ...
Page 88: ... 88 ...
Page 89: ... 89 ...
Page 90: ... 90 ...
Page 91: ... 91 ...
Page 92: ... 92 ...
Page 112: ......
Page 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...