2. Enter up to 16 digits. Use the key to enter “*”, “#”, “,” (pause), “T”
(switch to DTMF tone dialing), “P” (switch to pulse dialing) or “+”
(international code). Use the key to delete one character at a time.
3. Press
when you have finished editing.
10.5.2: Service Call Interface
For the Service Call feature, you can choose whether the system employs cellular or
PSTN communication.
To program the Service Call interface:
1. From the Programming menu, select Communications, Service Call,
Interface [9532].
2. Select either GSM or PSTN.
10.6: Communications Options
10.6.1: Line Monitor
The Line Monitor feature monitors both the PSTN telephone line and the GSM network. If
a problem is detected with either of these, a Media Loss event is registered in the log.
To program the Line Monitor setting:
1. From the Programming menu, select Communications, Comm.
Options, Line Monitor [95401].
2. Select Enabled or Disabled.
10.6.2: Periodic Test Interval
The Periodic Test is a test transmission the system sends to notify the central station that
its reporting capability is fully functional.
Two options are available for the Periodic Test:
•
You can program the system to send a Periodic Test message
according to a chosen time interval. This time interval can be between
1 and 254 hours (approximately 10 days).
•
The system calculates automatically the time the Periodic Test is sent
according to the last four digits of the account number. Automatically
calculated tests can be sent daily, weekly or monthly according to the
Auto Interval option –
see 10.6.4: Auto Interval
. This feature ensures that
the central station is not inundated by test reports at any given time.
,
The Periodic Test event message is an unclassified event. This means that it does not
belong to any event group. If the Periodic Test Interval is programmed with any value
other than 000, the event message shall be sent.
To program the Periodic Test Interval:
1. From the Programming menu, select Communications, Comm.
Options, Test Interval [95402].
2. Enter the test interval (001-254 hours) or 255 for an automatically
calculated test interval.
3. Press
when the desired setting is displayed.
To disable the Periodic Test:
•
Program the Periodic Test Interval as 000.
Summary of Contents for infinite prime
Page 1: ......
Page 86: ... 86 Appendix A Menu Structure Legend Installer code required Master code required ...
Page 87: ... 87 ...
Page 88: ... 88 ...
Page 89: ... 89 ...
Page 90: ... 90 ...
Page 91: ... 91 ...
Page 92: ... 92 ...
Page 112: ......
Page 113: ...Copyright 2008 Electronics Line 3000 Ltd All rights reserved ...