Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
62/71
599 77 00-82 Rev. 01
EC1
EC1: Water fill solenoid valves blocked
EC1
The flowmeter has to fill water even with the solenoid valve not piloted
Checks to perform:
Open the drawer to
check which solenoid
valve is leaking and
replace it.
Repeat the
diagnostic cycle to
check for any further
alarms.
Does the solenoid
valve start filling with
water as soon as the
appliance is turned on?
Open the drawer where the solenoid
valve leaks to check and measure
between the wiring connectors of the
respective solenoid valve and the
appliance body if there are
dispersions
(fig.6 and tab. 1).
Is there any dispersion?
Replace the main circuit
board and repeat the
diagnostic cycle to check for
any further alarms.
Does the
appliance fill with
water when the
appliance is turned
off?
Replace the main circuit board
and repeat the diagnostic cycle to
check for any further alarms.
Replace the wiring and repeat the diagnostic cycle to check for any further
alarms.
NO
NO
NO
Check that all the connectors are correctly inserted
!
Fig. 6
Between J18-1 and J18-3 wash solenoid valve
Between J18-4 and J18-6 pre-wash solenoid valve
Between J20-1 and J20-3 third solenoid valve
Between J20-4 and J20-6 hot water solenoid valve
Tab. 1
MAIN CIRCUIT
BOARD
3rd SOLENOID
VALVE
WASH
PRE-
WASH
HOT
WATER
∞
Ω
If there are burns on the circuit board,
see page 69
!
Y
E
S
Y
E
S
Y
E
S