![Electrolux Inspiration EWX11831 TC3 Service Manual Download Page 60](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385060.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
60/71
599 77 00-82 Rev. 01
Checks to perform:
Checks to perform:
Checks to perform:
Checks to perform:
Checks to perform:
E92
E92: protocol incongruence
E92
Inconsistency between configuration values on starting the appliance
E93
E93: Appliance configuration error
E93
Inconsistency between configuration values on starting the appliance
E94
E94: Incorrect configuration of washing cycle
E94
Inconsistency between configuration values on starting the appliance
E97
E97: Inconsistency between control selector version and configuration
data
E97
Discrepancy between programme configuration data and selector recognition data
E98
E98: Communication error between main PCB and Inverter board
E98
Incompatibility between the main circuit board and the Inverter board
Incorrect configuration possible.
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Incorrect configuration possible.
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Incorrect configuration possible.
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Incorrect configuration possible.
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!
Incorrect configuration possible.
Replace the main circuit board / Inverter board and repeat the diagnostic cycle to check for any further
alarms.