![Electrolux Inspiration EWX11831 TC3 Service Manual Download Page 49](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385049.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
49/71
599 77 00-82 Rev. 01
E5H
E5H: The Inverter board input voltage is too low (less than 175V)
E5H
The voltage should stay below 175V for at least 5 seconds
Checks to perform:
Are connectors J12 (main circuit board)
and J1IB (motor control board) properly
inserted?
Repair the connectors and repeat the
diagnostic cycle to check for any further
alarms.
Measure the continuity between
connectors J12-1, J12-2 (main circuit
board) and J1IB -1, J1IB -2 (motor control
board).
Replace the wiring and repeat the
diagnostic cycle to check for any further
alarms.
Replace the motor control board and
repeat the diagnostic cycle to check for
any further alarms.
Is the appliance working?
Replace the main circuit board and repeat
the diagnostic cycle to check for any
further alarms.
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!
NO
NO
NO
MAIN CIRCUIT
BOARD
ENGINE CONTROL
BOARD
Connector
Motor
Ω
Y
E
S
Y
E
S