E66
E66: Heating element power supply relay faulty
E66
Checks to perform:
Measure between the connector J6-1/J6-2 of
the main circuit board and the appliance body.
(Fig. 6)
Is there any dispersion?
Replace the circuit board and repeat the
diagnostic cycle to check for any further
alarms.
Detach the connectors and measure between
the heating element and the earth contact.
- fig. 19-
Is the circuit open?
Replace the heating element and repeat
the diagnostic cycle to check for any
further alarms.
Check/replace the wiring and repeat the
diagnostic cycle to check for any further alarms.
NO
NO
Check that all the connectors are correctly inserted
!
Fig. 6
MAIN CIRCUIT
BOARD
Ω
Ω
Washing heating element
Ω
J1
J19 J17 J1
J3
J7
J22 J20
J18 J15
J9
J13
J6
J1
Fig. 4
J12
Fig. 19
If there are burns on the circuit board,
see page 69
!
Y
E
S
Y
E
S