Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
48/71
599 77 00-82 Rev. 01
E5E
E5E: Communication error between Inverter board and main circuit
board
E5E
Communication protocol between the two boards not aligned
Checks to perform:
Checks to perform:
E5F
E5F: Inverter board fails to start the motor
E5F
Replace the motor control board and repeat the diagnostic cycle to check for any further alarms.
Replace the motor control board and repeat the diagnostic cycle to check for any further alarms.
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!