![Electrolux Inspiration EWX11831 TC3 Service Manual Download Page 34](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385034.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
34/71
599 77 00-82 Rev. 01
Is the door closed
correctly?
E42
E42:
Problems opening door
E42
Maximum time exceeded (255 seconds)
Checks to perform:
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!
Detach the connectors and
measure on the component
(fig. 9):
- between connectors 3 and
4, the circuit must not be
open (measure the
resistance value of the
PTC).
- on the other hand,
between connectors 4 and
5, the circuit must be open
(the numbers are printed on
the component).
Is the door interlock ok?
To check the wiring, with the door
open, measure on the following
wiring connectors:
- between wire J13-1 and J13-2,
the circuit must NOT be open
(measure the resistance value of
the PTC).
- between wire J13-2 and J13-3,
the circuit must be OPEN.
Is the system ok?
Replace the
door lock and
repeat the
diagnostic cycle
to check for any
further alarms.
Replace the door lock.
Is the appliance working correctly?
Check the mechanical coupling
between the door lock and the door
latch. Is the system efficient?
Close the door correctly and
repeat the diagnostic cycle to
check for any further alarms.
Replace the door latch/the door
Replace the main circuit board
and repeat the diagnostic cycle
to check for any further alarms.
Repeat the diagnostic cycle to
check for any further alarms
Measure the continuity
between connector J13 (main
circuit board) and the door lock
connector.
Is the wiring ok?
Replace the
wiring and
repeat the
diagnostic cycle
to check for any
further alarms.
Replace the main circuit board and repeat the diagnostic
cycle to check for any further alarms.
NO
NO
NO
NO
NO
NO
Fig. 9
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S