Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
28/71
599 77 00-82 Rev. 01
Checks to perform:
Checks to perform:
E24
E24: Sensing circuit of the component (triac) controlling the drain
pump faulty
E24
E31
E31: The analogue pressure switch provides the main circuit board
with a signal outside the limits
E31
Replace the circuit board and repeat the diagnostic cycle to check for any further alarms.
Measure that the circuit is closed
between J3-1, J3-2, J3-3 and the connector
of the analogue pressure switch
(they are three independent wires)
(
see fig. 7)
.
is the wiring between the main circuit board and
the analogue pressure switch ok and is it
connected correctly on both sides?
Reconnect and/or replace the wiring and repeat
the diagnostic cycle to check for any further
alarms.
Replace the analogue pressure switch and
repeat the diagnostic cycle to check for any
further alarm codes.
Is the appliance displaying the same alarm
code again?
NO
Replace the main circuit board and repeat
the diagnostic cycle to check for any further
alarm codes.
Fig. 7
Check that all the connectors are correctly inserted
!
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 69
!
DISPLAY
CIRCUIT
BOARD
Analogue pressure
switch
Ω
Y
E
S
If there are burns on the circuit board,
see page 69
!
Y
E
S