![Electrolux Inspiration EWX11831 TC3 Service Manual Download Page 50](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385050.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
50/71
599 77 00-82 Rev. 01
Checks to perform:
E62
E62: Overheating during washing
E62
The temperature of the NTC probe exceeds 88
C for more than 5 mins.
MAIN CIRCUIT
BOARD
Ω
Ω
Washing heating
element
5.7 ÷ 6.3K
(20°C)
5.7 ÷ 6.3K
(20°C)
Ω
Fig. 6
Measure the NTC probe
between terminals J3-4 and
J3-5 of the main circuit
board connector.
Is the value correct?
(between 5.7 and 6.3K
at
20°C)
Run the diagnostic cycle
and fill with water up to the
door level to make sure the
heating element is
completely submerged.
Measure between the wiring
connector J6-1/J6-2 and the
appliance body.
(see fig 6)
Is the circuit open?
Detach the connector and
measure between the
heating element and the
earth contact.
- (see fig. 19)-
Is the circuit open?
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
Detach the connector and
measure the value directly
on the NTC probe.
- (see fig. 18)-
Is the value correct?
(between 5.7 and 6.3K
at
20°C)
Replace the heating
element and repeat the
diagnostic cycle to check
for any further alarms.
Replace the circuit board
and repeat the diagnostic
cycle to check for any
further alarms.
Check/replace the wiring and repeat the diagnostic cycle to check
for any further alarms.
NO
NO
NO
NO
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!
Fig. 18
Fig. 19
Y
E
S
Y
E
S
Y
E
S
Y
E
S