Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
46/71
599 77 00-82 Rev. 01
E5C
E5C: The Inverter board input voltage is too high (beyond 430V)
E5C
The voltage should stay above 430V for at least 5 seconds
Checks to perform:
Measure the mains voltage and make sure
it is within the nominal range.
Is the mains voltage correct?
Wait for the mains voltage to return to
nominal conditions and repeat the
diagnostic cycle to check for any further
alarms.
Replace the motor control board and
repeat the diagnostic cycle to check for
any further alarms.
If there are burns on the circuit board,
see page 69
!
Check that all the connectors are correctly inserted
!