![Electrolux Inspiration EWX11831 TC3 Service Manual Download Page 22](http://html.mh-extra.com/html/electrolux/inspiration-ewx11831-tc3/inspiration-ewx11831-tc3_service-manual_2385385022.webp)
Guide to diagnostics of EWX11831 electronic controls
2013 TS/DT-mdm FCPD-dp
22/71
599 77 00-82 Rev. 01
Run the diagnostic cycle and fill all the trays with water
(phases 2,3,4,5,6)
Are all the trays filling with water?
E13
E13: Water leaks
E13
Maximum overall water fill time exceeded (sum of all water fills between one drain phase
and the next to avoid exceeding the maximum volume)
Checks to perform:
Repair the drain circuit and repeat
the diagnostic cycle to check for any further
alarms.
Repair the water circuit of the pressure switch
and repeat the diagnostic cycle to check for
any further alarms.
Replace the main circuit board and repeat the diagnostic cycle to check for any further alarms.
Is the drain pipe positioned
correctly and not causing the siphon
effect?
(fig.1)
Is the pressure switch's water circuit
efficient (leaking/clogged)?
(fig. 2)
Check whether the tap is open, if the water
pressure is too low and make sure the tubes are
connected and not kinked
Is one or are all the solenoid valves not
working?
Replace the solenoid valve and repeat the
diagnostic cycle to check for any further alarms.
Is the resistance measurement of the solenoid
valve approximately 3.5÷4.5K
? (Measure it
directly on the solenoid valve without wiring)
-(see
fig. 3)
-
Replace/repair the wiring and repeat the
diagnostic cycle to check for any further alarms.
Reconnect the connector and measure
approximately 3.5÷4.5K
on the solenoid valve
wiring connector on the circuit board side
(fig.4):
Between J18-1 and J18-3 wash
Between J18-4 and J18-6 pre-wash
Between J20-1 and J20-3 third solenoid valve
Between J20-4 and J20-6 hot water
Is the solenoid valve wiring ok?
Replace the main circuit board and repeat the
diagnostic cycle to check for any further alarms.
Repair the water circuit and repeat
the diagnostic cycle to check for any further
alarms.
Is the washing machine's water
circuit efficient (leaking)?
NO
NO
NO
NO
N
O
NO
NO
Check that all the connectors are correctly inserted
!
If there are burns on the circuit board,
see page 69
!
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S
Y
E
S