Pag. 116 di 152
10.4.2
Example of configuration file: “Events.xmbf”
The file contains only the data indicated in the
Data (hex)
columns
RECORD #0: FILE HEADER
RECORDS DEFINITION STRUCTURE
Data (hex)
Description
04
Header size (Bytes)
EA
Data records size (Bytes)
00
Reserved
02
ID Flags
RECORD #1: DATA RECORD
VARIABLES DEFINITION STRUCTURE
Data (hex)
Description
00
Reserved
80
Descriptor List Size (Bytes)
08 02 FF 00 00 00 07 F6
Internal var: Max data-file size
= 2038 Bytes
06 01 04 00 00 02
Internal var: Max number of report files
= 2
08 02 04 01 00 00 00 1E
Internal var: Voltage Dip/Sag & Undervoltage Threshold
= 30 V
08 02 04 02 00 00 00 28
Internal var: Voltage Dip/Sag & Undervoltage Restore Threshold
= 40 V
06 01 04 03 00 46
Internal var: Voltage Dip/Sag Max Duration
= 70 Cycles
08 02 04 04 00 00 01 04
Internal var: Voltage Swell & Overvoltage Threshold
= 260 V
08 02 04 05 00 00 00 FA
Internal var: Voltage Swell & Overvoltage Restore Threshold
= 250 V
06 01 04 06 00 46
Internal var: Voltage Swell Max Duration
= 70 Cycles
08 02 04 07 00 00 09 C4
Internal var: Current Peak & Overcurrent Threshold
= 2500 A/100
08 02 04 08 00 00 07 D0
Internal var: Current Peak & Overcurrent Restore Threshold
= 2000 A/100
06 01 04 09 00 46
Internal var: Current Peak Max Duration
= 70 Cycles
0C 07 FF 81 00 00 00 00 00 00 00 00
Internal var: Timestamp (main clock - WALL TIME)
= 1 january 1970 0.00.00 +00:00 GMT +00:00 DST
08 02 FF 85 00 00 00 00
Internal var: Serial number
= 0
06 01 FF 84 00 00
Internal var: Slave ID
= 0
04 87 FF 81
External multiple var: Timestamp (main clock - WALL TIME)