2-3
PRODUCT DATA SHEET
Revision Y06-02
Service Manual - KN Series
Model Indoor Unit
KN-30
Model Outdoor Unit
OU830
Installation Method of Pipe
Flared
Characteristics Units
Cooling
Only
Cooling
Heating
Btu/hr 28,300 28,300
30,500
Capacity
(1)
kW 8.30 8.30
8.94
Power input
(1)
kW
2.94
2.94
2.88
EER (Cooling) or COP(Heating)
(1)
W/W
2.82
2.82
3.10
Energy efficiency class
C C
D
Power supply
V/Ph/Hz
220-240V/Single/50Hz
Rated current
A
12.3
12.3
12.3
Starting current
A
80
Circuit breaker rating
A
25
Fan type & quantity
Centrifugal x 1
Fan speeds
H/M/L
RPM
740/700/620
Air flow
(2)
H/M/L
m3/hr
1200/1120/985
External static pressure
Min-Max
Pa
N/A
Sound power level
(3)
H/M/L
dB(A)
61/59/56
Sound pressure level
(4)
H/M/L
dB(A)
52/50/47
Moisture removal
l/hr
3.2
Condensate drain tube I.D
mm
32
Dimensions
WxHxD
mm
840x230x840 (Unit) / 950x46x950 (Frame)
Weight
kg
36 (unit) / 6 (Frame)
Package dimensions
WxHxD
mm
1011x333x931 (Unit) / 1013x145x1013(Frame)
Packaged weight
kg
40 (unit) / 7 (Frame)
Units per pallet
units
5(Unit) / 15(Frame)
INDOOR
Stacking height
units
5 Levels (unit) / 15 Levels (Frame)
Refrigerant control
Capillary
Compressor type, model
Rotary, Mitsubishi NN33VAAMT
Fan type & quantity
Propeller(direct) x 1
Fan speeds
H/L
RPM
850
Air flow
H/L
m3/hr
3150
Sound power level
H/L
dB(A)
69
Sound pressure level
(4)
H/L
dB(A)
59
Dimensions WxHxD
mm
900x860x340
Weight kg
78
Package dimensions
WxHxD
mm
985x907x435
Packaged weight
kg
82
Units per pallet
Units
6
Stacking height
units
2 Levels
Refrigerant type
R410A
Refrigerant chargless distance
kg/m
2.42kg/15m
Additional charge per 1 meter
g/m
30
Liquid line
In.(mm)
3/8"(9.53)
Suction line
In.(mm)
5/8"(15.88)
Max .tubing length
m.
Max.30
OUT
DO
OR
Connections between units
Max .height
difference
m. Max.15
Operation control type
Remote control
Heating elements
kW
Others
Crankcase
heater
(50W)
(1) Rating conditions in accordance with ISO 5151 and ISO 13253 (for ducted units) and EN 14511.
(2) Airflow in ducted units; at nominal external static pressure.
(3) Sound power in ducted units is measured at air discharge.
(4) Sound pressure level measured at 1 meter distance from unit.
2.3
KN 30 / OU8-30 R410A
Summary of Contents for KN 24 RC
Page 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Page 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Page 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Page 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Page 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...