5-18
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02
Service Manual - KN Series
5.12.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
°
C)
15
20
25
ENTERING AIR
WB OU COIL (
°
C)
TH
PI
TH
PI
TH
PI
-10
5.41 2.94 5.20 3.14 5.00 3.29
-7
5.82 3.02 5.61 3.18 5.41 3.36
-2
6.18 3.05 5.97 3.24 5.77 3.42
2
7.52 3.20 7.21 3.40 6.90 3.61
6
10.61 3.44
10.30 3.68
9.94 3.91
10
11.54 3.63 11.23 3.88 10.92 4.15
15
12.46 3.79 12.15 4.08 11.85 4.34
20
13.13 3.90 12.82 4.23 12.46 4.56
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.13
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
0.93
0.90
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.13.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
0.96
0.95
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Summary of Contents for KN 24 RC
Page 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Page 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Page 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Page 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Page 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...