5-14
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02
Service Manual - KN Series
5.9.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
°
C)
15
20
25
ENTERING AIR
WB OU COIL (
°
C)
TH
PI
TH
PI
TH
PI
-10
5.30 2.88 5.10 3.07 4.90 3.22
-7
5.71 2.95 5.50 3.11 5.30 3.28
-2
6.06 2.99 5.86 3.17 5.66 3.35
2
7.37 3.13 7.07 3.33 6.77 3.53
6
10.40 3.37
10.10 3.60
9.75 3.82
10
11.31 3.55 11.01 3.80 10.71 4.06
15
12.22 3.71 11.92 4.00 11.62 4.25
20
12.88 3.82 12.57 4.14 12.22 4.46
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.10
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
0.93
0.90
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.10.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
0.96
0.95
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Summary of Contents for KN 24 RC
Page 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Page 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Page 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Page 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Page 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...