5-2
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02
Service Manual - KN Series
5.1.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
°
C)
15
20
25
ENTERING AIR
WB OU COIL (
°
C)
TH
PI
TH
PI
TH
PI
-10
4.09 1.86 3.93 1.99 3.78 6.34
-7
4.40 1.91 4.24 2.02 4.09 6.46
-2
4.67 1.93 4.52 2.05 4.36 6.58
2
5.69 2.03 5.45 2.16 5.22 6.94
6
7.29 2.18
7.08 2.33
6.83 7.52
10
7.93 2.30 7.72 2.46 7.50 7.99
15
8.57 2.40 8.35 2.59 8.14 8.35
20
9.03 2.47 8.81 2.68 8.57 8.78
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.2
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.2.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Summary of Contents for KN 24 RC
Page 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Page 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Page 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Page 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Page 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...