5-6
PERFORMANCE DATA & PRESSURE CURVES
Revision Y06-02
Service Manual - KN Series
5.4.2
Heating Mode at 7.5m Tubing Connection.
230V : Indoor Fan at High Speed.
ENTERING AIR DB ID COIL (
°
C)
15
20
25
ENTERING AIR
WB OU COIL (
°
C)
TH
PI
TH
PI
TH
PI
-10
5.16 2.30 4.97 2.45 4.77 2.58
-7
5.56 2.36 5.36 2.49 5.16 2.63
-2
5.90 2.39 5.70 2.53 5.51 2.68
2
7.18 2.51 6.88 2.66 6.59 2.82
6
9.21 2.69
8.94 2.88
8.63 3.06
10
10.01 2.84 9.74 3.04 9.48 3.25
15
10.82 2.97 10.55 3.20 10.28 3.40
20
11.40 3.05 11.13 3.31 10.82 3.57
*
the above chart includes the weighted deicing infleuence.
LEGEND
TH –
Total Heating Capacity, kW
PI
– Power Input, kW
WB –
Wet Bulb Temp., (
o
C)
DB –
Dry Bulb Temp., (
o
C)
ID
–
Indoor
OU –
Outdoor
5.5
Capacity Correction Factor Due to Tubing Length (One Way)
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.01
1
0.98
0.97
0.96
0.95
0.94
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
5.5.1 Heating
TOTAL TUBING LENGTH
4m
7.5m
10m
15m
20m
25m
30m
40m
50m
1.02
1
0.99
0.99
0.98
0.97
0.97
---
---
*
Minimum recommended tubing length between indoor and outdoor units is 4m.
Summary of Contents for KN 24 RC
Page 50: ...9 2 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 2 KN 30 R410A...
Page 51: ...9 3 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 3 KN 36 R410A...
Page 52: ...9 4 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 4 KN 36T R410A...
Page 53: ...9 5 REFRIGERATION DIAGRAMS Revision Y06 02 Service Manual KN Series 9 1 5 KN 45T R410A...
Page 57: ...11 2 CONTROL SYSTEM Revision Y06 02 Service Manual KN Series 11 1 3 Main PCB Controller...