background image

Man. NVIP3 – Rel. 1.3 EN (UK) 

 

 

USER MANUAL 

 

 

 
 
 

 

 

 
 
 
 

 

 
 

 
 
 
 
 
 
 
 
 

 

Summary of Contents for NanoVIP3

Page 1: ...Man NVIP3 Rel 1 3 EN UK USER MANUAL...

Page 2: ...of power consumption High technological content careful material selection and full compliance with the latest regulations make this product the only one of its kind NanoVIP3 has been designed built...

Page 3: ...s Setup 20 4 2 3 Setup of Minimum Maximum Average Values 20 4 2 3 1 Integration Time Setup 20 4 2 3 2 Reset of Average Values Maximum Demand 20 4 2 3 3 Reset of Minimum Maximum Values 21 4 2 4 Counter...

Page 4: ...2 10 2 5 Manual Start 46 5 2 10 3 Inrush Current Display 45 5 2 11 Measurement Campaigns Menu 46 5 2 11 1 Measurement Campaigns 46 5 2 11 1 1 Campaign Name 46 5 2 11 1 2 Storing Rate 47 5 2 11 1 3 Man...

Page 5: ...mum average and maximum instant values on 4 quadrants absorbed and generated Absorbed and produced power counters kWh kVA kVAr which can be password protected Power quality analysis by measuring curre...

Page 6: ...low quality power presence of harmonics interruptions overloads dips unbalance in voltage phases etc which may bring about a production standstill and which may affect or reduce the life cycle of equi...

Page 7: ...nnected must be disconnected from any voltage source Before turning on the instrument make sure the maximum voltage at the voltmeter inputs is 1000VAC phase phase or 600VAC phase neutral If the instru...

Page 8: ...munity tests laid down in Standard IEC EN 61326 for the three specific applications specified below Use in industrial environment use in laboratories or test and measurement areas with electromagnetic...

Page 9: ...10 days of the consent of Elcontrol or the judicial authorities In the event of a report regardless of the object and reason therefore the purchaser shall pay the full amount indicated on the invoice...

Page 10: ...which correspond to the different phases Alternatively other Elcontrol Energy Net amperometric probes may be used depending on the specific measurement requirements For more details read Sect 9 Access...

Page 11: ...emory Card NanoVIP3 is equipped with a slot for a 2 GB uSD memory card which can be used to store measurement campaigns data Sect 5 2 11 2 fast transients Sect 5 2 10 1 and inrush currents Sect 5 2 10...

Page 12: ...examples of electrical connections are shown below See Sect 4 2 1 1 3 N 3 The 4th current probe is optional See Sect 9 Accessories 1 1 1 Do not use in the balanced three phase connection 3 N BL 3 N BL...

Page 13: ...Man NVIP3 Rel 1 3 EN UK 13 2 1 The probe for measuring the neutral current is optional...

Page 14: ...l 1 3 EN UK 14 Dispersion Measurement I can be combined with the previous schemes LMA clamp is optional See Sect 9 Accessories Example of connection on inverter DC clamp and additional voltage cables...

Page 15: ...easy use NanoVIP3 is equipped with a graphic LCD and a membrane keypad with snap domes for tactile feedback described in detail in Sect 4 1 2 The software architecture of the instrument is divided in...

Page 16: ...unctions represented by the icons on the white background 50160 are activated by pressing and holding down the relevant key Therefore the instrument has 12 function keys a joystick with the Enter func...

Page 17: ...terruptions and alarms menus Access to ALARMS Menu Scrolls up the pages of a measurement menu Moves cursor up in the setup pages Increases the selected value in the setup pages Access to EN 50160 Menu...

Page 18: ...CK SETUP 4 2 7 EN50160 SETUP 4 2 10 BOTTOM BAR SETUP 4 2 8 ALARMS SETUP 4 2 12 ALARM 1 2 SETUP 4 2 12 1 MINIMUM MAXIMUM AVERAGE SETUP 4 2 3 CONNECTION CHECK 4 2 1 6 TARIFFS SETUP 4 2 9 COMMUNICATION S...

Page 19: ...nnected i e when voltages higher than 600VAC must be measured the corresponding transformation ratio must be set default value 1 changing the values as needed 1 to 60000 4 2 1 3 Type of Voltage Voltag...

Page 20: ...2 I3 press and hold down or to increase scrolling speed the type of probe used for In i e Flex non amplified flexible sensor or AC DC clamp the sensor transformation ratio on In press and hold down or...

Page 21: ...following languages ENGLISH ITALIANO ESPA OL FRAN AIS DEUTSCH 4 2 6 LCD Setup The LCD SETUP page allows the user to set The backlight of the display Sect 4 2 6 1 LCD orientation Sect 4 2 6 2 LCD cont...

Page 22: ...ay sometimes be superfluous Therefore to make using the instrument even easier two different types of menus have been provided The FULL Menu which includes all the screens See Sect 5 The PARTIAL Menu...

Page 23: ...intervals access to the subpage to select the days on which the tariff is to be applied Sect 4 2 9 1 1 the cost of the kWh consumed in the relevant currency the yield of the kWh generated in the relev...

Page 24: ...he stored data related to all the grid disturbances that have been recorded 4 2 11 Serial Communication Setup This page allows the user to set the following parameters Data transfer speed baud rate 48...

Page 25: ...s L1 Qrms L2 Qrms L3 Srms 3F Srms L1 Srms L2 Srms L3 pf 3F pf L1 pf L2 pf L3 thdv 3F thdv L1 thdv L2 thdv L3 thdi 3F thdi L1 thdi L2 thdi L3 Freq In Unbal Vaux Iaux Paux Qaux Saux PFaux FRaux CosPhi L...

Page 26: ...nu 11 TRANSIENTSMenu press and hold key down for 3 to access menu 12 MEASUREMENT CAMPAIGNS Menu press and hold key down for 3 to access menu 5 1 Scrolling through Measurement Menus When accessing a me...

Page 27: ...MENU Sect 5 2 1 CURRENTS MENU Sect 5 2 2 POWER MENU Sect 5 2 3 AUX CH V COUNTERS MENU Sect 5 2 4 HARMONICS MENU Sect 5 2 5 x3 AUX CH I AUX CH P AUX CH Flowchart of MEASUREMENT MENUS in THREE PHASE WIT...

Page 28: ...IP3 Rel 1 3 EN UK 28 x3 WAVEFORMS MENU Sect 5 2 6 AUX CH WAVEFORMS AUX CHANNEL MENU x3 x3 x3 VOLTAGES MENU CURRENTS MENU POWER MENU COUNTERS MENU WAVEFORMS MENU x3 EN 50160 MENU Sect 5 2 8 x3 HARMONIC...

Page 29: ...Man NVIP3 Rel 1 3 EN UK 29 x3 ALARMS MENU Sect 5 2 9 x3 TRANSIENTS MENU Sect 5 2 10 x3 MEASUREMENT CAMPAIGNS Sect 5 2 11...

Page 30: ...P3 Rel 1 3 EN UK 30 VOLTAGES MENU Sect 5 3 1 CURRENTS MENU Sect 5 3 2 POWER MENU Sect 5 3 3 COUNTERS MENU Sect 5 3 4 HARMONICS MENU Sect 5 3 5 x3 x3 Flowchart of MEASUREMENT MENUS in SINGLE PHASE conn...

Page 31: ...Man NVIP3 Rel 1 3 EN UK 31 x3 WAVEFORMS MENU Sect 5 3 6 x3 EN 50160 MENU Sect 5 2 8 x3 ALARMS MENU Sect 5 2 9 x3 TRANSIENTS MENU Sect 5 2 10 x3 MEASUREMENT CAMPAIGNS Sect 5 2 11...

Page 32: ...voltages the relevant phase currents and the three phase or two phase voltage NOTE if another type of electrical connections without neutral is set this page will not be displayed When scrolling thro...

Page 33: ...st page of this menu displays the currents in each phase as well as in the three phase current or two phase current depending on the electrical connection and corresponding voltages When scrolling thr...

Page 34: ...to exit the Auxiliary Menu and return to the first page of the relevant menu 5 2 3 Power Menu The first page of this menu displays the active power W in each phase and in the three phase or two phase...

Page 35: ...l power and PF values can be reset as described in Sect 4 2 3 3 Load peaks and relevant PF i e the highest average power calculated on the basis of the integration time set Values can be reset as desc...

Page 36: ...4 2 3 3 related to the auxiliary channel Load peaks and relevant PF i e the highest average power calculated on the basis of the integration time set Values can be reset as described in Sect 4 2 3 2 r...

Page 37: ...erated kVarh in each phase and in the three or two phase connections The average PFs calculated as kWh kVAh ratio only the real part of the counters is taken into account the decimal part is not consi...

Page 38: ...ounters Menu pages press to access the page containing all the information regarding auxiliary channel counters In the AUX Menu the user can also access the other Auxiliary Channel Menus Voltages Curr...

Page 39: ...s that current comes before voltage thus the load is capacitive This page display the K factors of the phases This page displays the harmonic histogram of the voltage and current of phase L1 To select...

Page 40: ...ram of auxiliary voltage and current 5 2 5 1 Consulting Harmonic Histograms On any of the Harmonic Histograms pages press to access the function for selecting and scrolling through the single harmonic...

Page 41: ...voltage and current waveforms and relevant RMS values L2 voltage and current waveforms and relevant RMS values L3 voltage and current waveforms and relevant RMS values Neutral current waveform and rel...

Page 42: ...tioned reference Standard and the nominal values which have been set A table also shows the number of interruptions dips and swells which have occurred during the period monitored These pages display...

Page 43: ...This menu stores and displays the last 5 alarms to go off if any did go off For Alarm Setup see Sect 4 2 11 The menu automatically displays the page of the most recent alarm Each alarm is identified...

Page 44: ...alue indicates the peak phase current threshold over which the instrument will identify the presence of a transient Set 0 to disable this transient search function 5 2 10 1 4 In Threshold This value i...

Page 45: ...the electrical connection therefore the channels will always be identified as 3PH and N even if a single phase two phase or three phase without neutral connection is being used 5 2 10 2 2 Current Thr...

Page 46: ...s Menu This menu allows the user to Set a Measurement Campaign Sect 5 2 11 1 View the data stored on the uSD card Sect 5 2 11 2 5 2 11 1 Measurement Campaigns Select Start Campaign to view the Measure...

Page 47: ...the bottom bar Sect 4 1 1 1 To stop the campaign return to the Menu where the Stop function appears and press to stop the campaign and return to the Measurement Campaigns Menu Sect 5 2 11 5 2 11 1 4 S...

Page 48: ...page displays the RMS current maximum average and minimum value and maximum demand load peaks are calculated on the basis of the integration time set and the relevant voltages Minimum and maximum curr...

Page 49: ...2 3 2 On any of the Power Menu pages press to access a series of pages containing all the information regarding auxiliary channel power The first page displays active reactive and apparent power as w...

Page 50: ...er calculated on the basis of the integration time set Values can be reset as described in Sect 4 2 3 2 related to the auxiliary channel 5 3 4 Counters Menu 1ph Counters of absorbed P Q and generated...

Page 51: ...ers Menu pages press to access the page containing all the information regarding auxiliary channel counters In the AUX Menu the user can also access the other Auxiliary Channel Menus Voltages Currents...

Page 52: ...other page see below In the AUX Menu the user can also access the other Auxiliary Channel Menus Voltages Currents Counters Harmonics Waveforms by selecting them with the relevant function keys Press t...

Page 53: ...ge press to access the page of auxiliary channel tracing In the AUX Menu the user can also access the other Auxiliary Channel Menus Voltages Currents Power Counters Harmonics by selecting them with th...

Page 54: ...libration centre used 6 2 Repair NanoVIP3 is a sophisticated electronic product designed by Elcontrol Energy Net Any attempt to repair the instrument without the necessary know how may pose a safety r...

Page 55: ...ible with WINDOWS XP WINDOWS VISTA and WINDOWS7 To install it launch the file SETUP EXE contained on the uSD card and follow the instructions provided Thanks to this software the user will be able to...

Page 56: ...P Q S F PF THD V THD I cos peaks minimums maximums averages max demands etc Neutral current Measured Three phase counters kWh kVArh kVAh both absorbed that generated Counters for each single phase kWh...

Page 57: ...1 Scale 2 0 25 0 05 FS 5 RMS I 20 IN clamp 1 Scale 3 0 25 0 05 FS 20 RMS I 50 IN clamp 1 Scale 4 0 25 0 05 FS 50 IN clamp 1 Power 0 5 0 05 FS Power Factor PF 0 5 Frequency 0 01 Hz 40 70Hz Active power...

Page 58: ...068 2 1 Operating temperature IEC 60068 2 2 Storing temperature Vibrations IEC 60068 2 6 Humidity IEC 60068 2 30 Humidity Overload IEC 60947 1 1 The instrument changes the voltage and current scale au...

Page 59: ...purposes or measurement conditions which are less common than standard measurement operations ACCESSORIES Code Description 4AAWS 1000A Clamp 4AR10 200A Clamp 4AAYW 5A Clamp 4AAZA Nanoflex 21cm 3000A f...

Page 60: ...ve power counter 0026 kVArh 3 ph Three phase reactive power counter 0027 S N Serial number 0028 S N Serial number 0029 V L1 Voltage L1 0030 V L1 Voltage L1 0031 V L2 Voltage L2 0032 V L2 Voltage L2 00...

Page 61: ...ctive power counter tariff T2 0104 kWh T2 Three phase active power counter tariff T2 0105 kWh T2 Three phase active power counter tariff T2 0106 kWh T3 Three phase active power counter tariff T3 0107...

Page 62: ...nt L1 0520 A1 h025 Harmonic No 25 current L1 0521 A2 h025 Harmonic No 25 current L2 0522 A2 h025 Harmonic No 25 current L2 0523 A3 h025 Harmonic No 25 current L3 0524 A3 h025 Harmonic No 25 current L3...

Page 63: ...ctive power L2 1037 kW L3 Active power L3 1038 kW L3 Active power L3 1039 kVAr L1 Reactive power calculated on L1 1040 kVAr L1 Reactive power calculated on L1 1041 kVAr L2 Reactive power calculated on...

Page 64: ...imum reactive power 1115 kVar max 3 ph Maximum reactive power 1116 kVar max 3 ph Maximum reactive power 1117 kVAr max 3 ph Load peak of reactive power 1118 kVAr max 3 ph Load peak of reactive power 11...

Page 65: ...reactive power L2 1185 kVArh cog lagging L2 Counter of generated reactive power L2 1186 kVArh cog lagging L3 Counter of generated reactive power L3 1187 kVArh cog lagging L3 Counter of generated react...

Page 66: ...ive power tariff T4 1245 kVarh T4 Three phase counter of generated reactive power tariff T4 1246 Inp1 Digital input counter 1 1247 Inp1 Digital input counter 1 1248 Inp1 Digital input counter 1 1249 I...

Page 67: ...1 Phase displacement of harmonic No 1 L3 H02 Harmonic 2 1658 Pf1 h02 Phase displacement of harmonic No 2 L1 1659 Pf1 h02 Phase displacement of harmonic No 2 L1 1660 Pf2 h02 Phase displacement of harmo...