![Edwards STP Series Instruction Manual Download Page 89](http://html.mh-extra.com/html/edwards/stp-series/stp-series_instruction-manual_2366164089.webp)
STP-iXA2205 Series Turbomolecular Pump
Nov. 10
79
Issue 1-h
4
OPERATION
Pin
Description
Pins for inputting the rotation INHIBIT signal.
The input pins are valid even when input operation port is set to
serial port.
When the pins (5)–(1) are shutoff, the STP pump does not
rotate despite the presence of a start signal. When these pins
are shutoff while the pump is operating, the pump will stop (see
Section 4.9.3)
When using this function, supply 12 to 24 VDC to the circuits
between (2)–(1) of the rotation INHIBIT enable signal.
Pins for inputting the input operation port select signal.
When 12 to 24 VDC is supplied to the pins between (4)–(1), the
input operation port will be set to the parallel port automatically,
and the input operation via the serial port is disabled.
When voltage is not supplied to the pins between (4)–(1), a
parallel port or any of three serial ports from COM1 to COM4
can be selected in the input operation port (see Section 5)
Pins for inputting the rotation INHIBIT enable signal.
The input pins are valid even when input operation port is set to
serial port.
When 12 to 24 VDC is supplied to the pins between (2)–(1), the
rotation INHIBIT signal input is enabled.
Table 21 - X2 REMOTE input signal pins (voltage input) (continued)
(1)
(4)
COM PORT SELECT IN
- +
12 to 24V DC
(1)
(2)
COM INHIBIT ENABLE IN
12 to 24V DC
- +
(1)
(5)
COM
- + INHIBIT IN
12 to 24V DC