Sensor
Warning condition trig-
gered (°C)
Alarm condition triggered
(°C)
Booster pump end cover temperature
▪ iXM3000
100
110
Dry pump motor thermal snap switch
▪ All variants
-
150
Booster pump motor thermal snap switch
▪ iXM3000
-
70
*
T Xcede+ only.
Refer to
on page 79 for information about alarms and automatic shut
down conditions.
If the system has an unplanned shut down, make sure that the cause of the shut down is
identified and corrected before restarting. If in doubt, contact supplier.
Note:
The high temperature alarms on Edwards vacuum pumping systems are system
protection trips and should be considered as an abnormal running condition. If a system
has tripped due to any high temperature alarm the system should be examined and the
reason for the alarm identified. Once the fault has been corrected the system should be
left for a minimum of 30 minutes before attempting to restart.
8.4 Events
8.4.1 PDT Events
Table 37
Events
Warning message on PDT
Action message on PDT
on page 82
Check equipment newly connected
on page 82
Event 253.63 - Accessory oload
on page 82
on page 82
Event 255.63 - Accessory oload
on page 82
on page 82
Event 257.63 - Front Port oload
on page
82
on page 83
Note:
Some of these warnings apply to pump sensors that are only present on some dry
pumping system variants.
Some of these warnings apply to accessories and can only be encountered if the
particular accessory is installed.
10/2020 - ©Edwards Limited
Page 81
M56635880_D
M56635880_D - Fault finding
Summary of Contents for iXM Series
Page 1: ...Dry Pump System iXM INSTRUCTION MANUAL M56635880_D Original instructions edwardsvacuum com...
Page 101: ...This page has been intentionally left blank...
Page 102: ...This page has been intentionally left blank...
Page 103: ...This page has been intentionally left blank...
Page 104: ...edwardsvacuum com...