Figure 15 Mains input supply connector - Han® K 4/4
A. Low volt pin configuration
B. High volt pin configuration
A. Low volt pin configuration
B. High volt pin configuration
1. Mounting screw
2. Coding pin
3. Insert stranded wire
4. 2.5 mm hex (Allen) key
1. Mounting screw
2. Coding pin
3. Insert stranded wire
4. 2.5 mm hex (Allen) key
Pin identification
Pin 1
Phase 1
Pin 2
Phase 2
Pin 3
Phase 3
Pin 4
Not connected
PE
Protective earth
Torque settings for connector pins
Cable size (mm
2
)
Maximum torque setting (Nm)
6
2
10
3
16
4