background image

 

Configuring

 

your

 

system

 

I.

 

Entering

 

Programming

 

mode

 

The Programming mode is for you to configure 
the system.  

If the system is in Disarmed “Alarm off” mode, to 
enter the Programming mode, follow the steps 
below.   

 

 

 

   

PROBLEM?   

 

 

 

 

 

7

  

Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to 

help you make a perfect installation.

 

Step 1. Press “

” key. 

 the screen will prompt you to enter the 

Master PIN code. 

  P -  M o d e   E n t e r   
    M -  C o d e   . . . .   

  

Step 2.

 Key in 

“0000”

 (default 

“Master”

 PIN 

code) within 10 sec. 

 

Step 3. Press “OK

” 

 The following message is displayed for 

2 sec. 

 

    P r  o g r a m   M e n u    
M a k e   a   S e  l e  c t  I  o n

  

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

During keying in the PIN code,

 

press

 “ 

 “ 

will clear the code field.  If the code 

field is empty, press

 “ 

  “

, the screen 

will exit and return to 

“Alarm off” 

screen.  

 

Step 4. 

Then the Programming Main menu will be 

displayed. 

 

    W a l  k   T e s t          
  G e n . S e t t I n g s   

 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

 

)

 

The cursor is indicated by a flashing 
underline found under the first character.  
It can be moved up & down by

 

pressing 

S

 “

&

 “

T

” 

key respectively. 

Step 5. 

Press 

” 

S

 “ ,”

T

 “

to move the cursor 

downwards or upwards.  The screen is 
also scrolled down or up respectively.  The 

following items can be selected. 

9

 

Walk Test 

9

 

Gen. Settings. 

9

 

D/- 

Step 6.

 After making a selection by moving the 

cursor to the desired item,

 

press

 “OK”

 to 

confirm the selection.  The display will 
show you the individual programming 
screen accordingly. 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

)

 

Pressing

 “ 

  “

, the screen will return to 

“Alarm off”

 screen. 

)

 

After Master code is programmed with 
new numbers, remember to enter the 
newly programmed codes when 
accessing Programming mode 
afterwards.     

)

 

In Programming mode, if no key is 
pressed within 10 minutes, the Control 
Panel will automatically exit 
Programming mode to “Alarm Off” mode 
and the LCD will go blank.

 

 

II.

 

General

 

Settings

 

In

 “General Settings” menu,

 the following 

parameters can be programmed at your 
discretion.  

 

 U s e r   P I N   c o  d  e s   
  M a s t  e r    P  I  N  

c  o d  e

 

E n t 

r y  T 

 (1)    

 E x i t   T i m e   (1)        
 A l a r m   L e n g t  h    (1)  
 C . U .   S i r e n          
 C . U .   T a m p e r         
 

E x i 

 S 

     

 E n t r y   S o u n d         
 

D o o r  C 

     

 I  n t e r f e r e n c  e       
 W a r n i  n g   B e e  p       
 

L a n g u a 

       

 

1. User PIN codes 

z

 

There are 4 user PIN codes that can be activated 
and programmed for use.  They are 

“User1”, 

“User2”, “Cleaner”

 and 

“Temp”

 codes. 

z

 

“User1” is used to regularly arm/disarm the sytem  

Summary of Contents for HA2000

Page 1: ...HA2000 HA2000Y Wirefree Alarm System 20 Zones Installation Operating Manual...

Page 2: ...present in your house Built in power supply All parts of the system are supplied with two years lifetime batteries the system can be installed in a place where 220V power supply is not available Easy...

Page 3: ...call us via our assistance hotline at the end of the notice Our technicians will have the pleasure to help you make a perfect installation 3 6V AA Size Lithium battery for Door Contact 3V CR2032 Lithi...

Page 4: ...en if the EDEN HA2000 system allows you to manage up to 20 accessories keep in mind that it is not necessary to protect all the rooms in your house it is important to protect the main entrances or tho...

Page 5: ...s these keys to move the cursor and scroll the display upwards or downwards 5 Key In Programming mode or Users menu use this key for deleting a digit canceling the selection aborting the current scree...

Page 6: ...er tighten z Close the lid and tighten the large lid fixing screw with a coin III Getting Started Step 1 Find a suitable location for the Control Panel to be installed Step 2 Insert the batteries You...

Page 7: ...T to move the cursor downwards or upwards The screen is also scrolled down or up respectively The following items can be selected 9 Walk Test 9 Gen Settings 9 Devices Step 6 After making a selection...

Page 8: ...ear the code field Pressing while the code field is empty the screen will return to General Settings screen the original PIN Code is retained Step 4 The screen will return to the previous screen where...

Page 9: ...screens the value displayed on the screen or the option that the cursor underlined is the current setting of each item If it is not necessary to change the current setting just press to escape 3 Entr...

Page 10: ...i m e O f f z Press S T keys to select the option z Press OK to confirm z Chime Low is set as factory default N NO OT TE E If Chime Low or Chime High is selected when an Entry Door Contact or PIR is...

Page 11: ...TE E The categories of devices are listed as followings 9 HA2000M Open Contact DC 9 HA2000P PIR detector PIR 9 HA2000S Smoke detector SD 9 HA2000R Remote Controller RC 9 HA2000K Remote Keypad KP 9 HA...

Page 12: ...n to indicate a successful transmission z Battery The Remote Controller uses one CR2032 3V 230 mAh Lithium battery as its power source Battery life is over 2 years in a normal domestic environment The...

Page 13: ...ntroller StepC8 Press OK adding a Remote Controller is now completed screen returns to the Device menu N NO OT TE E Zone number is automatically assigned by the Control Panel Press all the learning se...

Page 14: ...activated door opened or door closed the LED will light z When the cover is opened and the tamper switch is violated the LED will light z When the tamper condition persists every time the Open Contac...

Page 15: ...entered the Control Panel will respond with a Burglar Alarm z If the Open Contact has been set to Entry and triggered when the system is in Disarmed mode the Control Panel will sound a ding dong Chim...

Page 16: ...to Device menu PIR Detector HA2000P With Digitalized Adaptive Signal Processor DASP algorithm enables this PIR to pick up movements within an assigned area and signals the Control Panel to activate t...

Page 17: ...z Battery z The PIR uses one 3 6 V Lithium battery as its power source The PIR will have a typical battery life of 5 years at an average of 20 activations a day z Low battery detection operates at a...

Page 18: ...ected Help Watch is confirmed you are requested to choose between Personal Attack or Medical device mode P e r s o n a l A t t a c k M e d i c a l N NO OT TE E P for Personal Attack Help Watch Control...

Page 19: ...they will work in 2 different device modes Step F5 After the detected device is confirmed you are requested to choose between Internal Alarm or External Alarm mode I n t e r n a l A l a r m E x t e r...

Page 20: ...sound with Burglar message for dialler and Control Panel HA2000P HA2000M 24 Hour H Detector supervised 24h 24h f Sirens Ext Int and Control panel strong and swept sound with Burglar message for dialle...

Page 21: ...vice choose Remove Device in the Device menu The display will show S T A R T T Step 1 Use S T keys to scroll the display All the used zones with the device names are listed in order of the zone number...

Page 22: ...owing message will be displayed in Step 3 P l e a s e a d d o n e d e v i c e The message will be displayed for 2 sec then the screen returns to Device menu You are requested to add a detector or Remo...

Page 23: ...side to side twice Operation I User Menu 1 Power Saving Waking Up The Control Panel is battery powered to conserve the battery power and to prolong the battery life the Control Panel is put in Power...

Page 24: ...d by using the Remote controller or the Remote Keypad If the Outdoor Bell Box is included in the system it will beep once and the strobe will flash once after the Exit Delay has expired 2 Stopping the...

Page 25: ...lay time is up the Control Panel will sound three short beeps The system is in Home Arm Mode and the LCD display stays blank N NO OT TE E You can also put the system into the Home mode by pressing the...

Page 26: ...Contact or PIR Sensor is triggered the Control Panel will activate the alarm providing the Entry Delay has expired z If the 24 HR Fire alarm Personal Attack Alarm device is triggered the Control Pane...

Page 27: ...to enter your PIN code Step 2 If the PIN code is correct then the alarm sounding will be stopped and the display will show the source of the alarm A l a r m e d b y P I R Z 0 1 The sensor which trigg...

Page 28: ...l respond as below z When the system is in Disarmed mode the Control Panel will generate an Internal alarm where the Control Panel will sound its internal siren not activate its External Siren Bell Bo...

Page 29: ...l be displayed S T A R T T Step 3 The log can now be scrolled up and down and viewed with the S T keys the most recent event will be at the start Step 4 An example of logged event is given below where...

Page 30: ...rmance z In a corner to give the widest view z Where its field of view will not be obstructed e g by curtains ornaments etc z Mounting Method z The PIR is designed to be mounted on either a flat surfa...

Page 31: ...o mount the Open Contact by either Self adhesive installation or Screw mounting z Self adhesive mounting Step 1 Clean the surface with a suitable degreaser Step 2 Remove the protective covering from o...

Page 32: ...JP1 in the normal Off position Screw the Cover assembly back onto its base Step 7 Installation is now completed N NO OT TE E Ensure the TEST NORMAL jumper is in the normal Off position when testing i...

Page 33: ...tamper protection by putting the Control Panel into Programming Mode N NO OT TE E The Programming Mode will automatically quit after 10 minutes if no keys are pressed z Loosen front screw with a coin...

Page 34: ...ay requesting you to Enter Code Step 6 Enter key 7 and 9 Step 7 All logs cleared and the display shows Clear Log z If key is pressed then the unit will revert to normal alarm on mode z If more than 17...

Page 35: ...T LED Orange z Orange LED on Arm Memory z Orange LED flash system failure panel tamper AC fault sensor temper sensor out of order open door N NO OT TE E When idle all LED s are off After any key press...

Page 36: ...empt to open the lid or to detach HA2000K from its mounting surface z Tamper protection is disabled when in Test Mode z Mounting KP 9 z Remove the 2 slide out sections of front cover z Using the 2 mou...

Page 37: ...you have forgotten the Pin Code or anything wrong happened in the HA2000K you can reset the HA2000K to factory default and reinitialize it Reset to factory default Step 1 Remove one of the batteries...

Page 38: ...________ Phone No 3 ______________________________ Phone No 4 ______________________________ Phone No 5 ______________________________ Phone No 6 ______________________________ This information is con...

Page 39: ...extra wired detectors NC loop Double tamper protection back mount cover LED light Default Test mode Transmitted signals Opening Closing Weak battery Tamper Tamper closed Supervision and Test Mode Bat...

Page 40: ...W 69mm H Waterproof IP44 Polycarbonate UV resistant Guaranty This product is guarantee 4 years except the batteries The first year is by standard exchange The 3 years left the guarantee is for parts...

Page 41: ...PROBLEM 7 Do not HESITATE to call us via our assistance hotline at the end of the notice Our technicians will have the pleasure to help you make a perfect installation...

Reviews: