PROBLEM?
12
Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to
help you make a perfect installation.
z
The Control Panel is capable of detecting
following fault events:
9
Control Panel Low Battery
9
Device Low Battery
9
Device and Control Panel Tamper
9
Interference
1. Fault Message Display
z
When any fault situation persists, the Control
Panel will respond as below when it is in
Disarmed mode:
z
A warning beep will sound at every 30
seconds (if
“Warning Beep On”
is set).
z
When any key is pressed, the Control
Panel will sound a two-tone fault sound
and the fault message will be displayed.
z
The fault message indicates the device
type with its zone number and name and
the nature of the fault. The fault
message alternates at 2-second intervals
with the normal
“Alarm Off”
message.
P I R L o w B a t t e r y
Z 0 5 H A L L . . . . . . . .
A
lternating with:
A l a r m O f f
z
If more than one faulty situation persists,
individual fault message will be displayed
sequentially at 2-sec intervals.
z
The fault display will be cleared automatically
when the fault has been remedied. If not, the
display will be shown every time a key is pressed.
z
Keying in the user codes while the fault display is
shown will allow arming and disarming of the
system.
<
<
N
N
O
O
T
T
E
E
>
>
)
Even when the fault message is cleared,
the fault event is still retained in the
“Log”
.
)
Any key stroke during the two-tone
warning sound is ignored.
2. Device Tamper
When any of Door Contact, PIR detector, Remote
Keypad or Control Panel is sabotaged, the Control
Panel will respond as below:
z
When the system is in Disarmed mode, the
Control Panel will generate an Internal alarm
where the Control Panel will sound its internal
siren, not activate its External Siren, Bell Box or
Auto Dialer ..etc.
z
When the system is in Away arm or Home mode, a
burglar alarm will be generated where the Control
Panel will activate its internal siren, External
Siren, Bell Box, Auto Dialer…etc.
z
After the alarm, if the tamper condition persists, a
Tamper fault message together with the two-tone
fault sound will be generated every time the
Control Panel is accessed. The warning beep will
also be produced every 30 seconds.
z
When the tamper condition is remedied, the fault
display will be cleared automatically or when the
tamper condition persists, entering and then
exiting the Programming mode once will also
clear the tamper display and warning.
<
<
N
N
O
O
T
T
E
E
>
>
)
Remember to enable the Control Panel
Tamper during normal operation to
ensure that the Control Panel is
protected from sabotage.
3. Interference
If the
“Int. Detect On”
is set in Programming mode,
interference will be detected if it is present for more
than 30 sec. The Control Panel will respond as below:
z
When the system is in Disarm mode, the Control
Panel will sound a warning beep every 30 sec. and
the Interference fault message will be displayed
when the Control Panel is accessed.
z
When the system is in Away arm mode, the
Control Panel will give an Internal alarm where
the Control Panel will sound its internal siren only.
<
<
N
N
O
O
T
T
E
E
>
>
)
Interference alarm will be activated only
once even if the interference persists.
z
When the system is in Home mode, the Control
Panel gives a warning beep every 30 seconds. If
the Control Panel is accessed by pressing
“OK”
key, the following message will be displayed: