PROBLEM?
10
Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to
help you make a perfect installation.
z
During the Entry Delay period, if a sensor with
Instant attribute is triggered, the Control Panel will
activate the alarm immediately, otherwise the
control Panel will not respond.
2. Disarmed Mode
z
In the DISARMED mode; if a 24Hour alarm, Fire
alarm, Personal Attack alarm, and Tamper alarm is
triggered, the Control Panel will activate the alarm
immediately.
z
If any sensors other than the above are triggered,
the Control Panel will not respond.
z
If an
“Entry”
Door Contact or PIR Detector is
triggered, the Control Panel will sound a ding-
dong door chime, ( if Door Chime function is
enabled)
z
Dual-Key Alarm Activation:
z
Personal Attack Alarm:
A Personal Attack alarm can be triggered
at the Control Panel by pressing keys 1
and 3 simultaneously for 2 seconds.
z
Fire
Alarm:
A Fire alarm can be triggered at the
Control Panel by pressing keys 4 and 6
simultaneously for 2 seconds.
z
Medical
Alarm:
A Medical alarm can be triggered at the
Control Panel by pressing keys 7 and 9
simultaneously for 2 seconds.
3. Home Mode
z
If a
“Burglar”
Door Contact or PIR Detector is
triggered, the alarm will sound immediately.
z
If a
“Home Omit”
Door Contact or PIR Detector
is triggered, the Control Panel will not respond.
z
If an
“Entry”
Door Contact or PIR Detector is
triggered, the Control Panel will activate the alarm
providing the Entry Delay has expired.
z
If a
“Home Delay”
Door Contact or PIR Sensor is
triggered, the Control Panel will activate the alarm
providing the Entry Delay has expired.
z
If the 24 HR, Fire alarm, Personal Attack Alarm
device is triggered, the Control Panel will activate
the alarm immediately.
During Entry Delay period,
z
If a Door Contact or PIR with instant
attribute is triggered again, the Control
Panel will activate the alarm immediately.
z
If
“Home Delay”
Door Contact or PIR is
triggered, the Control Panel will ignore it.
z
If a Door Contact or PIR with Non-Instant
attribute is triggered, the Control Panel
also ignores it.
z
Dual-Key Alarm Activation:
z
Personal Attack Alarm:
A Personal Attack alarm can be triggered
at the Control Panel by pressing keys 1
and 3 simultaneously for 2 seconds.
z
Fire
Alarm:
A Fire alarm can be triggered at the
Control Panel by pressing keys 4 and 6
simultaneously for 2 seconds.
4. Alarm Definition
“Burglar Alarm”
1. An alarm condition where the Control Panel,
External Siren are activated in concert, where
a burglar message is transmitted (if Auto-
Dialer is available)
2. The Control Panel will sound swept frequency
alarm tone in high volume.
“Fire Alarm”
1. An alarm condition where the Control Panel,
External Siren are activated in concert, where
a Fire message is transmitted (if Auto-Dialer is
available)
2. The Control Panel will sound pulsed fire alarm
output in high volume.
“Personal Attack Alarm”
1. An alarm condition where the Control Panel,
External Siren are activated in concert, where
a Personal Attack message is transmitted (if
Auto-Dialer is available)
2. The Control Panel will sound swept frequency
alarm tone in high volume.
3. This alarm can’t be silenced by the Remote
Controller.
“Internal Alarm”
1. An alarm condition where only the Control