enable the LED indicator to flash every
time the Door Contact is operated.
Step 2.
Fit the base on the door frame using
either the double sided adhesive pad or
the screws provided.
Step 3.
Fit the magnet on the door using the
small double sided adhesive pad or the
screws provided. Aligning the magnet by
the arrow as shown.
<
<
N
N
O
O
T
T
E
E
>
>
PROBLEM?
16
Do not HESITATE to call us via our assistance hotline (at the end of the notice). Our technicians will have the pleasure to
help you make a perfect installation.
)
The magnet should not be more than 30
mm from the detector when the door is
closed.
)
Ensure the tamper switch spring is
positioned so that it makes contact with
the mounting surface through the tamper
switch aperture.
)
Windows can be protected in a similar
way to doors. When fitting to a window
fix the magnet to the moving part and the
door switch to the frame.
Step 4.
Fix the Cover assembly on its base and
secure with the screw.
Step 5.
Test the Door Contact by opening and
closing the door or window when the
Control Panel is in “
Walk Test
” mode.
The LED will flash every time the door is
opened or closed.
Step 6.
Remove the Cover assembly; put the
TEST / NORMAL jumper (JP1) in the
normal ‘Off’ position. Screw the Cover
assembly back onto its base.
Step 7.
Installation is now completed.
<
<
N
N
O
O
T
T
E
E
>
>
)
Ensure the TEST / NORMAL jumper is in
the normal “Off” position when testing is
finished.
z
Using the Extension Terminal.
The Extension Terminal is provided to enhance
installation flexibility and to serve a wider range of
your meds.
The Extension terminal is most useful in the following
cases.
z
If the Open Contact cannot be mounted on
the door frame, you can connect an additional
“
extension magnet switch
” to the
“
Extension Terminal
” and mount the Open
Contact remotely.
z
More than one window and door can be
protected by a Open Contact using the
additional magnet and extension magnet
switch. The switches must be wired to the
auxiliary terminal block as shown:
z
Any device with N.C. (Normally Closed) dry
contact, such as broken glass detectector,
Smoke Sensor, gas detector, water leabag
detector etc, can be connected to the
“
Extension Terminal
” Making the Open
Contact served as an “
Universal Transmit
”.
<
<
N
N
O
O
T
T
E
E
>
>
)
The Extension Terminal form a closed
loop with the device connected to it.
When the Loop is opened (the device is
triggered), the Open Contact is activated.
)
The device connected to the Extension
Terminal is in series with the internal
magnet Switch. That means both of
them can work together at the same
time.
)
You have the choice to Use the