417101637_Lub-O-Mat
- 39 -
Rev. 03-07.12
6.3.2 Key functions
Key
Description
MENU/EXIT function entry and exiting of the menu levels
(keep keys pressed down together)
Modify set values upwards
Modify set values downwards
Start the pump
Stop the pump
Confirmation key (ENTER) for set values
Test function (endurance test)
6.3.3 Initial startup / Delivery status
In the as-delivered condition of
Lub-O-Mat
is configured the pump as follows.
Operation mode:
pulse, multiplication, factor n = 1
Status:
pump in the operationg state “OFF”
6.3.4 Venting the metering pump
ATTENTION
Particular caution is required when handling chemical metering media!
Metering media may escape which may cause skin irritation, depending on their
properties. Therefore, before venting, always observe the product datasheet of the
metering medium to prevent any type of injury!
NOTE
To ensure an optimal suction performance, the stroke length should be set to 100% and
the maximum stroke frequency.
In the event that pump has no suction or insufficient suction, the correct connection must
be checked.
ATTENTION
It is only possible to modify the stroke length setting when the pump is running.
Open the vent screw approximately 1 turn
Hold a suitable collection vessel under the vent connection
Press the Test key until the metering medium escapes from the venting outlet.
Hold down the Test key for a further 60 seconds to fill the pump head fully with the
product.
Reclose the vent screw.
Press the Test Key again until the metering medium is visible through the metering pipe,
until it reaches approximately 2 cm in front of the inoculation valve.
Close the clear cover which protects the function keys, and seal it if necessary.
NOTE
If no metering medium enters the metering pipe, repeat the aerating.
6.3.5 Adjusting the metering pump
How already described, by the electronic integrated in the metering pump EMP II, the
incoming pulses of flow sensor may also be integer multiplied or divided.
Also the adjustment of the metering amount per stroke is possible.
Summary of Contents for 183042
Page 14: ...417101637_Lub O Mat 14 Rev 03 07 12 5 8 Stromlaufplan Abb 5 8...
Page 24: ...417101637_Lub O Mat 24 Rev 03 07 12 11 Konformit tserkl rung...
Page 37: ...417101637_Lub O Mat 37 Rev 03 07 12 5 8 Circuit diagram Fig 5 8...
Page 47: ...417101637_Lub O Mat 47 Rev 03 07 12 11 Declaration of conformity...
Page 60: ...417101637_Lub O Mat 60 Rev 03 07 12 5 8 Sch ma de circuit fIG 5 8...
Page 70: ...417101637_Lub O Mat 70 Rev 03 07 12 11 D claration de conformit...
Page 71: ......