417101637_Lub-O-Mat
- 40 -
Rev. 03-07.12
6.3.5.1 Setting the pulse multiplier or divisor
To menu operating mode will be set if incoming water flow pulses are multiplied or divided.
At pulse multiplication causes every incoming pulse in “n” (setting factor) metering stroke.
At pulse division will be of the incoming pulses in “n” (setting factor) cause 1 metering stroke.
6.3.6 Indicators in “External pulse processing” operation mode
Display in operation
Meaning
Pos Description
Fig. 6.2
Pulse multiplication
(Example:
10 external pulses
become 20 strokes)
1
Pulse memory active
2
Number of pulses received
3
Set factor
Fig. 6.3
Pulse division
(Example:
10 external pulses
become 20 strokes)
6.3.6.1
Selecting
Press key function “MENU/EXIT”.
The main menu appears with the
“operation mode” menu item
highlighted.
Press START/STOP key.
The operation mode menu which
appears is divided into: internal,
pulse and current.
Select the “Internal” operation
mode using the Up or Down key.
Press START/STOP key.
Fig. 6.4
The “Internal operation mode” submenu appears and offers the following selection:
-
Multiplication
-
Division
Select the desired indicator using the Up or Down key.
Press START/STOP key.
The setting is applied immediately and the pump returns to the main menu.
Press the key function “MENU/EXIT”
The display shows the current or recently set operation mode.
The new factor (n) can be selected in pulse operation setting mode.
Summary of Contents for 183042
Page 14: ...417101637_Lub O Mat 14 Rev 03 07 12 5 8 Stromlaufplan Abb 5 8...
Page 24: ...417101637_Lub O Mat 24 Rev 03 07 12 11 Konformit tserkl rung...
Page 37: ...417101637_Lub O Mat 37 Rev 03 07 12 5 8 Circuit diagram Fig 5 8...
Page 47: ...417101637_Lub O Mat 47 Rev 03 07 12 11 Declaration of conformity...
Page 60: ...417101637_Lub O Mat 60 Rev 03 07 12 5 8 Sch ma de circuit fIG 5 8...
Page 70: ...417101637_Lub O Mat 70 Rev 03 07 12 11 D claration de conformit...
Page 71: ......