5.
Installation
5.1
Overview of connection arrangement:
Lub-O-Mat
Fig. 5.1
Pos Description
1
Non-return valve
2
Flow sensor ̶ water
3
Fresh water connection
4
Connection for suction lance plug (3-pin)
5
Suction pipe or suction lance connection
6
EMP II E60 metering pump
7
Terminal box with fuse
8
Main switch and display elements
9*
Flow meter (OGM Plus oval gear meter ) ̶
belt lubricant concentrate
10
Metering line
11
Metering valve
12
Sampling
13
Mixing chamber
14
Consumer connection
* optional
5.2
Wall mounting:
Lub-O-Mat
Fig. 5.2
The following parts are supplied for wall
mounting:
Qty
Description
Artcle no.
4
Wood screws, 8 x 60 mm
413110926
4
Dowel pinx
417200005
4
Distance roll
386313-02
4
Washer
413500363
These parts are available in full in a kit
bearing article number 283575.
NOTE
Take care to ensure ease of access for purposes of servicing!
Install the metering station in the immediate vicinity of the storage facility
(canister, barrel, container or tank), to keep the suction line as short as possible.
Summary of Contents for 183042
Page 14: ...417101637_Lub O Mat 14 Rev 03 07 12 5 8 Stromlaufplan Abb 5 8...
Page 24: ...417101637_Lub O Mat 24 Rev 03 07 12 11 Konformit tserkl rung...
Page 37: ...417101637_Lub O Mat 37 Rev 03 07 12 5 8 Circuit diagram Fig 5 8...
Page 47: ...417101637_Lub O Mat 47 Rev 03 07 12 11 Declaration of conformity...
Page 60: ...417101637_Lub O Mat 60 Rev 03 07 12 5 8 Sch ma de circuit fIG 5 8...
Page 70: ...417101637_Lub O Mat 70 Rev 03 07 12 11 D claration de conformit...
Page 71: ......