417101637_Lub-O-Mat
- 31 -
Rev. 03-07.12
4.1.2 Plant with several concentration (e.g.: with 3 concentrations)
Fig. 4.2
Pos. Description
A
Spraying system (single & multiple distribution systems)
B
1. Concentration
C
2. Concentration
D
3. Concentration
E
Fresh water connection according to DIN / DVGW
F
Product storage (canisters, barrels, containers, tanks)
G
Lub-O-Mat
, 2,5/4,3/7,2/11,2
1
Needle-type control valve
2
Valve time control
3
Water distributor
4
Suction distributor
4.2
Metering system
The belt lubricant is metered at a rate which is proportional to the water flow rate. This
ensures a precise, uniform concentration and a homogenous conveyor track lubrication
solution even when there are fluctuations in the amount of solution used.
4.3
Water pressure adjustment
In order to maintain a constant water pressure, an adjustable pressure reducer has to be
mounted into the line upstream from the metering unit.
The pressure setting required will depend mainly on the length of the connected distribution
lines (ie taking account of the pressure loss).
For a satisfactory spraying pattern at the spray jets, a minimum pressure of 1.5 bars at the
jets is required.
Summary of Contents for 183042
Page 14: ...417101637_Lub O Mat 14 Rev 03 07 12 5 8 Stromlaufplan Abb 5 8...
Page 24: ...417101637_Lub O Mat 24 Rev 03 07 12 11 Konformit tserkl rung...
Page 37: ...417101637_Lub O Mat 37 Rev 03 07 12 5 8 Circuit diagram Fig 5 8...
Page 47: ...417101637_Lub O Mat 47 Rev 03 07 12 11 Declaration of conformity...
Page 60: ...417101637_Lub O Mat 60 Rev 03 07 12 5 8 Sch ma de circuit fIG 5 8...
Page 70: ...417101637_Lub O Mat 70 Rev 03 07 12 11 D claration de conformit...
Page 71: ......